background image

 

 

Example#2

 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.

 

 

                                    

 

MaxTime

 

 

 

 

 

Sleeping(MinTime)       

  

  sleeping             sleeping  

  

        sleeping 

 

 

0H

                 15

th

 M                30

th

 M            45

th

 M               

1H

                                                2H 

          

 

 

 

 

 

Example#3 

based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. 

 

 

 

                                                                                                       

MaxTime 

 

 

 

 

    

 

sleeping             sleeping

 

        ...

 

 

 

0H

             15

th

 M            

30

th

 M 

          45

th

 M              1H  

1H 10

th

 M

     1H 25

th

 M           1H 40

th

 M        1H 55

th

 M       

2H 10

th

 M

                    

 

 

 

 

 

 

 

Notes : 

1)

 

The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it does not 

collect data. 

2)

 

The data collected is compared with the last data reported. If the data variation is greater than the ReportableChange value, 

the device reports according to MinTime interval. If the data variation is not greater than the last data reported, the device 

reports according to MaxTime interval. 

3)

 

We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is too low, the device wakes up 

frequently and the battery will be drained soon. 

4)

 

Whenever the device sends a report, no matter resulting from data variation, button pushed or MaxTime interval, another 

cycle of MinTime/MaxTime calculation is started. 

 

 

 

 

 

 

 

Wakes up and 

collects data 

3.6V   

Does not report   

Wakes up and 

collects data 

3.6V 

Does not report 

 

 

Wakes up and 

collects data 

3.6V 

Does not report   

 

 

Wakes up and 

collects data 

REPORTS 3.6V 

 

Wakes up and 

collects data 

REPORT 3.6V 

Wakes up and 

collects data 

REPORTS 3.6V 

 

Wakes up and collects data 

3.5V |3.5-3.6|=0.1 

REPORTS 3.5V 

Wakes up and 

collects data 

3.5V   

Does not report   

Wakes up and 

collects data 

3.5V   

Does not report   

Wakes up and 

collects data   

3.5V   

Does not report   

Wakes up and 

collects data 3.5V 

Does not report 

 

 

 

Wakes up and 

collects data   

3.5V   

Does not report   

 

Wakes up and 

collects data 

REPORTS 3.5V 

Wakes up and 

collects data 

3.6V 

  Does not report   

Users push the button, 

REPORTS 3.5V. 

Recalculate MaxTime. 

 

 

Summary of Contents for R719A

Page 1: ...nology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other partie...

Page 2: ...f Content 1 Introduction 2 2 Appearance 2 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 6 1 Battery Installation 10 6 2 Device Installation 12 7 Important Maintenance Instr...

Page 3: ...LoRa spread spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For example a...

Page 4: ...a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Improved power manag...

Page 5: ...Network Joining Never joined the network Turn on the device and it will search for the network to join Had joined the network not at factory setting Turn on the device and it will search for the prev...

Page 6: ...to detect the current voltage value per Min Interval Battery voltage 0x01 0 1V Geomagnetic Detect Threshold 0x28 40 Range 0x14 0xFFFF 0x14 is the most sensitivity Vehicle parking trigger When a car p...

Page 7: ...of the device to prevent incorrect setting which will cause false detection of parking status Description Device Cmd ID Device Type NetvoxPayLoadData Config ReportReq R719A 0x01 0x59 MinTime 2bytes U...

Page 8: ...xample 1 based on MinTime 1 Hour MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime MaxTime Sleeping MinTime Sleeping MinTime Note MaxTime MinTime Data will only be report accordin...

Page 9: ...recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matte...

Page 10: ...commended to be installed in the middle of the parking space for best results Make sure that there is no obstruction above the device when the device is turned on The device is turned off by default A...

Page 11: ...gure 1 Figure 1 Step 2 Remove the middle plastic cover The plastic cover is shown in the red area in Figure 2 Please note that the plastic cover is rectangular and pay attention to the direction when...

Page 12: ...3 Figure4 Step 4 After installing the battery as Figure 5 Close the plastic cover and the back cover again and tighten the six screws Figure 5 Positive Pole Negative Pole Positive Electrode Negative...

Page 13: ...needs to be replaced within 10 minutes after the device is turned on users need to the magnet approach to the top cover for 10 seconds to restore the factory settings after replacing the battery The...

Page 14: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Reviews: