4.

 

Set Up Instruction 

On/Off 

 

Power On 

DC12V adapter 

Turn On 

DC12V power supply, the green indicator flashing once means turn on successfully. 

Turn Off (Restore to factory setting)  Press and hold the function key for 5 seconds, and the green indicator flashes 20 times 

Power Off 

Remove DC12V adapter 

Note 

1. On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor 

inductance and other energy storage components 

2. The first five seconds after power on, the device will be in engineering test mode 

 

Network Joining 

 

Never Join the Network 

Turn on the device to search the network 

The green indicator keeps on for 5 seconds: success 

The green indicator remains off: fail 

Had Joined the Network 

(Not restore to the factory setting) 

Turn on the device to search the previous network 

The green indicator keeps on for 5 seconds: success 

The green indicator remains off: fail 

Fail to Join the Network 

Suggest to check the device verification information on the gateway or consult your platform 

server provider 

 

Function Key 

 

Press and Hold for 5 Seconds 

Restore to the factory setting / turn off 

The green indicator flashes 20 times: success 

The green indicator remains off: fail 

Press once 

The device is in the network: the green indicator flashes once and the 

device sends a data report 

The device is not in the network: the green indicator remains off+ 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for R718PA5

Page 1: ...s document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice ...

Page 2: ... Content 1 Introduction 2 2 Appearance 3 3 Main Feature 3 4 Set Up Instruction 4 5 Data Report 5 5 1 Example of ReportDataCmd 5 5 2 Example of ConfigureCmd 6 6 Installation 7 7 Important Maintenance Instruction 8 ...

Page 3: ...ow power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equipment wireless security systems industrial monitoring Main features include small size low power consumption transmission...

Page 4: ...magnetic material object Main body IP Rating IP65 IP67 Optional Compatible with LoRaWANTM Class A Frequency hopping spread spectrum technology Configuring parameters and reading data via the third party software platforms and set alarms via SMS text and email optional Applicable to the third party platforms Actility ThingPark TTN MyDevices Cayenn Indicator Function Key NO2 Sensor ...

Page 5: ...ice to search the network The green indicator keeps on for 5 seconds success The green indicator remains off fail Had Joined the Network Not restore to the factory setting Turn on the device to search the previous network The green indicator keeps on for 5 seconds success The green indicator remains off fail Fail to Join the Network Suggest to check the device verification information on the gatew...

Page 6: ...age index 5 1 Example of ReportDataCmd FPort 0x06 Bytes 1 1 1 Var Fix 8 Bytes Version DeviceType ReportType NetvoxPayLoadData Version 1 byte 0x01 the Version of NetvoxLoRaWAN Application Command Version DeviceType 1 byte Device Type of Device The devicetype is listed in Netvox LoRaWAN Application Devicetype doc ReportType 1 byte the presentation of the NetvoxPayLoadData according the devicetype Ne...

Page 7: ...8157000000000000000000 configuration success 8157010000000000000000 configuration failure 2 Read R718PA5 device parameter Downlink 0257000000000000000000 Device Return 8257000A003C0000000000 device current parameter Description Device Cmd ID Device Type NetvoxPayLoadData Config ReportReq R718PA Series 0x01 0x57 MinTime 2bytes Unit s MaxTime 2bytes Unit s Reserved 5Bytes Fixed 0x00 Config ReportRsp...

Page 8: ...he figure below which can be attached to the surface of an iron object during installation which is convenient and quick In order to make the installation firmer please use screws purchased separately to fix the device to the wall or other surface as Figure below NO2 Sensor is fixed by screws that needs two screws purchased separately in the middle Note Do not install the device in a metal shielde...

Page 9: ...melt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit boards and delicate structures Do not clean the device with strong chemicals detergents or strong detergents Do no...

Reviews: