background image

 

 

12 

7. Information about Battery Passivation 

Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many 

advantages including low self-discharge rate and high energy density.      

 

However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium 

anode and thionyl chloride if they are in storage for a long time or if the storage temperature is too high. This lithium chloride 

layer prevents rapid self-discharge caused by continuous reaction between lithium and thionyl chloride, but battery passivation 

may also lead to voltage delay when the batteries are put into operation, and our devices may not work correctly in this situation.    

 

As a result, please make sure to source batteries from reliable vendors, and it is suggested that if the storage period is more 

than one month from the date of battery production, all the batteries should be activated. 

 

 

If encountering the situation of battery passivation, users can activate the battery to eliminate the battery hysteresis. 

 

ER14505 Battery Passivation: 

7.1 To determine whether a battery requires activation 

Connect a new ER14505 battery to a resistor in parallel, and check the voltage of the circuit. 

If the voltage is below 3.3V, it means the battery requires activation.   

 

7.2 How to activate the battery 

a. Connect a battery to a resistor in parallel   

b. Keep the connection for 5~8 minutes 

c. The voltage of the circuit should be 

3.3, indicating successful activation. 

 

Brand 

Load Resistance 

Activation Time 

Activation Current 

NHTONE 

165 Ω 

5 minutes 

20mA 

RAMWAY 

67 Ω 

8 minutes 

50mA 

EVE 

67 Ω 

8 minutes 

50mA 

SAFT 

67 Ω 

8 minutes 

50mA 

Note:   

If  you  buy  batteries  from  other  than  the  above  four  manufacturers,  then  the  battery  activation  time, activation  current,  and 

required load resistance shall be mainly subject to the announcement of each manufacturer. 

Summary of Contents for R718NL3 Series

Page 1: ...Wireless Light Sensor and 3 Phase Current Meter Model R718NL3 Wireless Light Sensor and 3 Phase Current Meter R718NL3 User Manual...

Page 2: ...3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Information about Battery Passivation 12 7 1 To determine whether a battery requires activation 12 7 2 How to activate the...

Page 3: ...th 3 x630A Clamp On CT Range 10A 630A 1 When the current of the device that is 75A or below is less than 100mA the current is reported as 0 When the current of the device that is above 75A is less tha...

Page 4: ...gh third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consumption a...

Page 5: ...s not set to default Turn on the device and it will search for the previous network to join The green indicator light stays on for 5 seconds joins the network successfully The green indicator light re...

Page 6: ...in Interval 0x0E10 3600s CurrentChange 0x0064 100 mA Subject to factory settings IlluminanceChange 0x0064 100 Lux Subject to factory settings Current and Illuminance Detection When the function key is...

Page 7: ...Unit 1mA Current3 2Bytes Unit 1mA Mulitplier1 1Byte the real current1 should convert with Current Multiplier 0x02 Battery 1Byte unit 0 1V Mulitplier2 1Byte the real current2 should convert with Curre...

Page 8: ...mdID 1 byte DeviceType 1 byte Device Type of Device NetvoxPayLoadData var bytes Max 9bytes 1 Configure report parameters MinTime 1min MaxTime 1min CurrentChange 100mA IlluminanceChange 100Lux Downlink...

Page 9: ...ge i e BatteryVoltageChange 0 1V MaxTime sleeping sleeping 0H 15th M 30th M 45th M 1H 1H 10th M 1H 25th M 1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 3 6V Does not report Wakes up and col...

Page 10: ...me Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data vari...

Page 11: ...s time If the current variation does not exceed the default value the data will be reported regularly according to MaxTime Press the Key of the device to start sampling data and report the data after...

Page 12: ...ed to set the torque as 4kgf to ensure the device is impermeable Installation Diagram Screw Fixation Screw Fixation R718NL3 Wire to be detected Wire to be detected Wire to be detected Current Directio...

Page 13: ...orage period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to eli...

Page 14: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...