background image

                                                                                                           

     

 

 

 

 

Wireless Light Sensor and 3-Phase Current Meter 

 

Model: R718NL3

 

 

 

 

 

 

 

 

Wireless Light Sensor and   

3-Phase Current Meter   

 
 

R718NL3   

User Manual 

 

     

 

 

 

 

 

 

 

 

 

 

Summary of Contents for R718NL3 Series

Page 1: ...Wireless Light Sensor and 3 Phase Current Meter Model R718NL3 Wireless Light Sensor and 3 Phase Current Meter R718NL3 User Manual...

Page 2: ...3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Information about Battery Passivation 12 7 1 To determine whether a battery requires activation 12 7 2 How to activate the...

Page 3: ...th 3 x630A Clamp On CT Range 10A 630A 1 When the current of the device that is 75A or below is less than 100mA the current is reported as 0 When the current of the device that is above 75A is less tha...

Page 4: ...gh third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consumption a...

Page 5: ...s not set to default Turn on the device and it will search for the previous network to join The green indicator light stays on for 5 seconds joins the network successfully The green indicator light re...

Page 6: ...in Interval 0x0E10 3600s CurrentChange 0x0064 100 mA Subject to factory settings IlluminanceChange 0x0064 100 Lux Subject to factory settings Current and Illuminance Detection When the function key is...

Page 7: ...Unit 1mA Current3 2Bytes Unit 1mA Mulitplier1 1Byte the real current1 should convert with Current Multiplier 0x02 Battery 1Byte unit 0 1V Mulitplier2 1Byte the real current2 should convert with Curre...

Page 8: ...mdID 1 byte DeviceType 1 byte Device Type of Device NetvoxPayLoadData var bytes Max 9bytes 1 Configure report parameters MinTime 1min MaxTime 1min CurrentChange 100mA IlluminanceChange 100Lux Downlink...

Page 9: ...ge i e BatteryVoltageChange 0 1V MaxTime sleeping sleeping 0H 15th M 30th M 45th M 1H 1H 10th M 1H 25th M 1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 3 6V Does not report Wakes up and col...

Page 10: ...me Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data vari...

Page 11: ...s time If the current variation does not exceed the default value the data will be reported regularly according to MaxTime Press the Key of the device to start sampling data and report the data after...

Page 12: ...ed to set the torque as 4kgf to ensure the device is impermeable Installation Diagram Screw Fixation Screw Fixation R718NL3 Wire to be detected Wire to be detected Wire to be detected Current Directio...

Page 13: ...orage period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to eli...

Page 14: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Reviews: