6. Installation 

This device has a waterproof function. When the device is used, the back of it can be attached to the 

iron surface, or two ends of it

 

can be secured on the wall by screws. 

When the magnet is close to or far away, the sensor will be triggered to send a report.   

The gap between the Hall sensor and the magnet should be less than 

3cm

 during installation.   

When the installation clearance is greater than 3cm, the device will not be able to trigger the signal. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                                                                     
 
 
 
 
 

1.

 

The Wireless 2-gang Hall Type Open/Close 

Detection Sensor (R718LB2) has a built-in 

magnet (see Figure 1 below). 

It can be attached to the surface with iron material 

during installation. 

To make the installation more secure, please use 

screws (purchased separately) to fix the device on 

the wall or other objects (see Figure 2 below). 

 

Comment: 

Do not install the device in a metal shielded box or 

in an environment surrounded by other electrical 

equipment to avoid affecting the wireless 

transmission of the device. 

  Figure 1 

             

Figure 1                

 

 

 

                             

Figure 2 

 

 

 

2. Tear off 3M release paper of Hall sensor and 

the magnet then attach to the door or window 

in parallel. 

 

Note: The mounting distance between the Hall 

sensor and the magnet should be less 

than 3cm. 

 

3. When the door or window is opened, the 

Hall sensor is separated from the magnet, 

and the Hall sensor sends status “1”. 

 

When the door or window is closed, the Hall 

sensor is close to the magnet, and the Hall 

sensor device sends status “0”. 

Summary of Contents for R718LB2

Page 1: ...ight Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed...

Page 2: ...3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 10 7 Information about Battery Passivation 13 7 1 To determine whether a battery requires activation 13 7 2 How to activate the...

Page 3: ...n methods LoRa spread spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For...

Page 4: ...Compatible with LoRaWANTM Class A Using frequency hopping spread spectrum technology Configurable parameters via third party software platform reading data and setting alarms via SMS text and email o...

Page 5: ...1st 5th second after power on the device will be in engineering test mode Network Joining Never joined the network Turn on the device to search the network to join The green indicator stays on for 5 s...

Page 6: ...he magnet removes the Hall sensor it will report the status 1 The distance between the magnet and the Hall sensor is greater than 3 cm Note The device report interval will be programmed based on the d...

Page 7: ...table Change Any number between 1 65535 Any number between 1 65535 Can not be 0 Report per Min Interval Report per Max Interval Description Device Cmd ID Device Type NetvoxPayLoadData Config ReportReq...

Page 8: ...sponse 8245003C003C0100000000 Current configuration Example for MinTime MaxTime logic Example 1 based on MinTime 1 Hour MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime MaxTime S...

Page 9: ...it is sleeping it does not collect data Wakes up and collects data 3 6V Does not report Wakes up and collects data 3 6V Does not report Wakes up and collects data REPORT 3 6V Wakes up and collects dat...

Page 10: ...er than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up f...

Page 11: ...th iron material during installation To make the installation more secure please use screws purchased separately to fix the device on the wall or other objects see Figure 2 below Comment Do not instal...

Page 12: ...nsor The Wireless 2 gang Hall Type Open Close Detection Sensor R718LB2 can be used in the following scenarios Door window Machine room door Archives Closet Refrigerators and freezers Cargo ship door G...

Page 13: ...12 If the magnet moves along the Y axis relative to the sensor it will cause repeated reports due to the magnetic field...

Page 14: ...passivation may also lead to voltage delay when the batteries are put into operation and our devices may not work correctly in this situation As a result please make sure to source batteries from rel...

Page 15: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Reviews: