5
5. Data Report
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable Change
Current Change
≥
Reportable Change
Current Change
<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0
Report
per Min Interval
Report
per Max Interval
The device will immediately send a version packet report and the vibration report data
The device sends data in the default configuration before any configuration is done.
Default setting:
MaxTime: Max Interval = 60 min = 3600s
MinTime: Min Interval = 60 min = 3600s
BatteryVoltageChange: 0x01 (0.1V)
R718DA Trigger:
When the device senses vibration and the ball is shaken, an alarm message will be reported.
The shaking alarm bit is “1”.
The static and non-shaking alarm bit is “0”.
Restore Function:
There are two ways for the ball to trigger an alarm.
One is not to report the recovery status after sending the alarm.
(default)
The other is to report the recovery status after the device stops vibrating for 5 seconds after sending the alarm.
The two ways can be executed before shipment or by LoRaWAN command configuration
Note:
The device report interval will be programmed based on the default firmware which may vary.
The interval between two reports must be the minimum time.
Please refer Netvox
LoRaWAN Application Command document
and
Netvox Lora Command Resolver
http://loraresolver.netvoxcloud.com:8888/page/index