background image

 

 

Restore configuration: 

 

Description 

Device  CmdID 

DeviceType 

NetvoxPayLoadData 

SetRestore 

ReportReq 

R718DA 

0x03 

0x1A 

RestoreReportSet (1byte) 

0x00_DO NOT report when sensor restore 

0x01_DO report when sensor restore 

Reserved 

(8Bytes,Fixed 0x00) 

SetRestore 

ReportRsp 

0x83 

Status 

(0x00_success) 

Reserved 

(8Bytes, Fixed 0x00) 

GetRestore 

ReportReq 

0x04 

Reserved 

(9Bytes, Fixed 0x00) 

GetRestore 

ReportRsp 

0x84 

RestoreReportSet (1byte) 

0x00_DO NOT report when sensor restore 

0x01_DO report when sensor restore 

Reserved 

(8Bytes,Fixed 0x00) 

 

(3) Do report after sensor stops vibrating 

Downlink

  031A010000000000000000 (0x01_DO report when sensor restore) 

Response

 

831A000000000000000000 (Configuration success) 

831A010000000000000000 (Configuration failure) 

(2) Read restore function: 

Downlink

    041A000000000000000000 

Response

    841A010000000000000000 (Current configuration) (report when sensor restore) 

 

Example for MinTime/MaxTime logic:   

 

Example#1

 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V

 

 

 

 

                     

MaxTime                                             MaxTime

 

 

 

 

                 

 

Sleeping(MinTime)    

                                        

  Sleeping(MinTime)  

 

    

 

 

 

 

 

 

 

Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BatteryVoltageChange 

value.   

Wake up and collects data 

REPORTS 3.6V 

 

 

Wakes up and collects data 

REPORTS 3.6V   

 

 

Wakes up and collects data 

REPORTS 3.6V 

 

 

Summary of Contents for R718DA

Page 1: ...Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other p...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Important Maintenance Instruction 10...

Page 3: ...tance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low...

Page 4: ...ectrum technology Configuration parameters can be configured through third party software platforms Data can be read and alerts can be set via SMS text and email Optional Applicable to third party pla...

Page 5: ...tor stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network to join The green indicator stays on for 5 seconds succ...

Page 6: ...Trigger When the device senses vibration and the ball is shaken an alarm message will be reported The shaking alarm bit is 1 The static and non shaking alarm bit is 0 Restore Function There are two wa...

Page 7: ...00 Configuration failure 2 Read device configuration parameters Downlink 021A000000000000000000 Response 821A003C003C0100000000 Current configuration Description Device CmdID Device Type NetvoxPayLoad...

Page 8: ...stops vibrating Downlink 031A010000000000000000 0x01_DO report when sensor restore Response 831A000000000000000000 Configuration success 831A010000000000000000 Configuration failure 2 Read restore fun...

Page 9: ...recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matte...

Page 10: ...r it is vibrating here take the mousetrap as a picture as shown below 3 The figure shows the vibration sensor R718DA applied to the scene of the mousetrap in the restaurant It can also be applied to t...

Page 11: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Reviews: