background image

3

5. Data Report

The device will immediately send a version package report and a report data with temperature and voltage values after the device is powered on.
The device sends data in the default configuration before any configuration is done.

Maximum time: Max Interval
Minimum time: Min Interval (by default, the current voltage value is detected every Min Interval)
Default reportchange:
Battery --- 0x01 (0.1V)
Air temperature default reportchange: 1

Note: The data transmission cycle of the device is subject to the real programming configuration before shipment.
The interval between two reports must be the minimum time
R718AD default Max Interval = 15min, Min Interval = 15min
(if there is special custom shipment, the setting will be changed according to customer requirements)
The data reported by the device can be decoded with the Netvox LoraWAN Application Command document and
http://www.netvox.com.cn:8888/page/index

Data report configuration and sending period are as following:

6. Command Configuration Setting

FPort

0x07

Bytes

1

1

Var(Fix =9 Bytes)

CmdID DeviceType

NetvoxPayLoadData

CmdID

– 1 bytes

DeviceType

– 1 byte – Device Type of Device

NetvoxPayLoadData

– var bytes (Max=9bytes)

Report Command Configuration Setting

Min Interval
(Unit:second)

Max Interval
(Unit:second)

Reportable
Change

Current

Change≥

Reportable Change

Current Change

Reportable Change

Any number between
1~65535

Any

number

between 1~65535

Can not be 0.

Report
per Min Interval

Report
per Max Interval

Description

Device

CmdID

DeviceTy

pe

NetvoxPayLoadData

ConfigReportRe

q

R718A

D

0x01

0x9C

MinTime(2

bytes

Unit:s)

MaxTime(2by

tes Unit:s)

BatteryChange

(1byte

Unit:0.1v)

TemperatureCh

ange(2byte

Unit:0.01

)

Reserved

(2Bytes,Fixed

0x00)

ConfigReportRs

p

0x81

Status(0x00

_success)

Reserved (8Bytes,Fixed 0x00)

ReadConfigRepo

rtReq

0x02

Reserved (9Bytes,Fixed 0x00)

ReadConfigRepo

rtRsp

0x82

MinTime(2

bytes

Unit:s)

MaxTime(2by

tes Unit:s)

BatteryChange

(1byte

Unit:0.1v)

TemperatureCh

ange(2byte

Unit:0.01

)

Reserved

(2Bytes,Fixed

0x00)

Reviews: