background image

 

 

Example#1 

based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V 

 

 

 

                    

 

Max Time                                            Max Time

 

 

 

 

                  

S

leeping (Min Time)                                             

S

leeping (Min Time

)       

 

 

 

1H                                               2H                                                3H 

     

 

 

 

Note:   

MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BatteryVoltageChange 

value.   

 

 

Example#2

 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. 

 

                                     

MaxTime

 

 

 

 

 

Sleeping (MinTime)                  sleeping                    sleeping                 sleeping 

 

 

0H

                 15

th

 M               30

th

 M            45

th

 M                

1H

                                                2H 

          

 

 

 

 
 
 
 

Example#3

 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. 

 

 

 

                                                                                                  

MaxTime 

 

 

 

 

  

   

sleeping           sleeping

         ...

 

 

 

0H

              15

th

 M             

30

th

 M 

         45

th

 M               1H   

1H 10

th

 M

      1H 25

th

 M           1H 40

th

 M        1H 55

th

 M        

2H 10

th

 M

         

              

 

 

 

 

 

 

 

 
 

Wakes up and 

collects data 

2.8V 

Does not report 

Wakes up and 

collects data 

REPORTS 2.8V 

 

Wakes up and 

collects data 

REPORT 2.8V 

Wakes up and 

collects data 

REPORTS 2.8V 

 

Wakes up and 

collects data 

2.7V |2.7-2.8|=0.1 

REPORTS 2.7V 

Wakes up and 

collects data 

2.7V 

Does not 

 

Wakes up and 

collects data 

2.7V   

Does not report 

Wakes up and 

collects data   

2.7V   

Does not report 

Wakes up and 

collects data 2.7V 

Does not report 

 

Wakes up and 

collects data 

2.7V 

Does not report 

 

Wakes up 

and collects 

data 

REPORTS 

 

Wake up and   

collects data 

REPORTS 2.8V 

Wakes up and 

  collects data 

REPORTS 2.8V   

Wakes up and   

collects data 

REPORTS 2.8V 

Wakes up and 

collects data 

2.8V   

Does not report 

Users push the button,   

REPORTS 2.7V. 

Recalculate MaxTime.

   

Wakes up and 

collects data 

2.8V 

Does not report 

Wakes up and 

collects data 

2.8V 

Does not report 

Summary of Contents for R313WA

Page 1: ...nology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology and is issued in strict confidential and shall not be disclosed to others parties in w...

Page 2: ...Table of Content 1 Introduction 2 2 Appearance 2 3 Main Features 3 4 Set up Instruction 3 5 Data Report 5 6 Seat Occupancy Delay Configuration 8 7 Installation 10 8 Important Maintenance Instruction 1...

Page 3: ...er communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automat...

Page 4: ...life 4 Set up Instruction On Off Power on Insert batteries users may need a screwdriver to open Insert two sections of 3V CR2450 button batteries and close the battery cover Turn on Press any functio...

Page 5: ...ification information on the gateway with your platform server provider Function Key Press and hold for 5 seconds Restore to factory setting Turn off The green indicator flashes for 20 times success T...

Page 6: ...f sending version package is once every 24 hours Data will be reported once per hour by default setting Default setting Maximum time 3600s Minimum time 3600s Battery 0x01 0 1V Disabletime 0x001E 30s D...

Page 7: ...ration failure 2 Read Configuration Downlink 025A000000000000000000 Response 825A003C003C01001E001E Current configuration Description Device Cmd ID Device Type NetvoxPayLoadData Config ReportReq R313W...

Page 8: ...1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 2 8V Does not report Wakes up and collects data REPORTS 2 8V Wakes up and collects data REPORT 2 8V Wakes up and collects data REPORTS 2 8V Wa...

Page 9: ...iguration logic includes DetectionTime and DisableTime DisableTime is the sampling period DetectionTime is the detecting period Please find further info regarding DisableTime and DetectionTime below 1...

Page 10: ...ected after triggered R313WA will report un pressure after 60 secs DetectionTime Example2 While DetectionTime is 60 secs and DisableTime is 30 secs pressure is detected during 25th sec R313WA will res...

Page 11: ...affecting the wireless transmission of the device 2 Tear off the 3M adhesive on the back of the sensor and stick the sensor to the seat 3 one of the 2 gang seat occupancy sensor detects external pres...

Page 12: ...y batteries and deform or melt some plastic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board...

Reviews: