background image

 

 

6.

 

Installation 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Tear off the 3M sticker on the back of the 

R313CC, and stick the body to a smooth wall. 
(Please do not stick it on a rough wall to avoid 
the device from falling off after a long time of 
use). 

Note:   

 

Please wipe the wall clean before installation 

to avoid dust on the wall which may affect 
the installation of the device. 

 

Do not install the device in a metal shielded 

box or in an environment with other 
electrical equipment around it to avoid 
affecting the wireless transmission of the 
device. 

 

 

2. Tear off the 3M sticker at the bottom of the   

reed switch and the magnet (as the red frame   
in the figure above).   

 

Then, stick the reed switch and the magnet to 
the door or window in parallel (as the figure on 
the right). 

 
Note:   

 

The installation distance between the reed 

  

 

switch and the magnet should be less than 
2cm. 

3. When the door or window is opened, the reed switch is 

separated from the magnet, and the device reports the data 
immediately. 

4. If it detects that the battery voltage exceeds the   

variation during Min Time, the data will be reported 
immediately. 

5. Whether the state of the reed switch status changes, the 

data will be reported regularly when the Max Time. 

Note: 

When the reed switch is closed, the status is “0”. 
When the reed switch is opened, the status is “1”. 

R313CC is suitable below scenarios: 

 

Door, window 

 

Drawer   

 

Archives 

 

Closet 

 

Refrigerators and freezers 

 

Cargo ship hatch 

The place needs to detect the opening and closing status. 

 

Installation Diagram of R313CC 

Summary of Contents for R313CC

Page 1: ...ogy Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice ...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Important Maintenance Instruction 10 ...

Page 3: ... other communication methods LoRa spread spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For example automatic meter reading building automation equipment wireless security systems industrial monitoring It has features like small size low power consumption long transmissio...

Page 4: ... data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Low power consumption and long battery life Note Battery life is determined by the sensor reporting frequency and other variables please refer to http www netvox com tw electric electric_calc html On this website users can find battery lifetime for va...

Page 5: ...nductance and other energy storage components 3 Press any function key and insert batteries at the same time it will enter engineer testing mode Network Joining Never joined the network Turn on the device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network The green in...

Page 6: ...by the Netvox LoRaWAN Application Command document and http loraresolver netvoxcloud com 8888 page index Sleeping Mode The device is on and in the network Sleeping period Min Interval When the reportchange exceeds setting value or the state changes send a data report according to Min Interval Low Voltage Warning Low Voltage 2 4V 5 Data Report Data report configuration and sending period are as fol...

Page 7: ... 0x00 Config ReportRsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s Battery Change 1byte Unit 0 1v Reserved 4Bytes Fixed 0x00 1 Command Configuration MinTime 1min MaxTime 1min BatteryChange 0 1v Downlink 016C003C003C0100000000 003C Hex 60 Dec Response 816C00000000000000...

Page 8: ... based on MinTime 15 Minutes MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime Sleeping MinTime sleeping sleeping sleeping 0H 15th M 30th M 45th M 1H 2H Wakes up and collects data 2 8V Does not report Wakes up and collects data 2 8V Does not report Wakes up and collects data REPORT 2 8V Wake up and collects data REPORTS 2 8V Wakes up and collects data REPORTS 2 8V Wakes up and...

Page 9: ...e reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data variation button pushed or MaxTime interval another cycle of MinTime MaxTime calculation is started Wakes up and collects data...

Page 10: ...reed switch and the magnet to the door or window in parallel as the figure on the right Note The installation distance between the reed switch and the magnet should be less than 2cm 3 When the door or window is opened the reed switch is separated from the magnet and the device reports the data immediately 4 If it detects that the battery voltage exceeds the variation during Min Time the data will ...

Page 11: ...melt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit boards and delicate structures Do not clean the device with strong chemicals detergents or strong detergents Do no...

Reviews: