background image

 

 

5. Data Report   

 

  Data report configuration and sending

 

period are as following: 

 

5.1 Example of ReportDataCmd 

FPort

0x06 

Bytes 

Var(Fix=8 Bytes) 

 

Version 

DeviceType  Report

 

Type 

NetvoxPayLoadData 

Version

– 1 byte –0x01

——

the Version of NetvoxLoRaWAN Application Command Version 

DeviceType

– 1 byte – Device Type of Device 

 

 

 

 

     

The device

 

type is listed in Netvox LoRaWAN Application Devicetype doc 

ReportType

 – 1 byte –the presentation of the NetvoxPayLoadData

according the devicetype 

NetvoxPayLoadData

– Fixed bytes (Fixed =8bytes)

 

Min Interval 

(Unit:second) 

Max Interval 

(Unit:second) 

Reportable Change 

Current Change≥ 

Reportable Change 

Current Change

Reportable Change 

Any number between 

1~65535 

Any number between 

1~65535 

Can not be 0. 

Report 

per Min Interval 

Report 

per Max Interval 

When the device is powered on and activated, it will immediately send a version package.   

Data will be reported once per hour by default setting. 

 

Default setting: 

Maximum time: 3600s 

Minimum time: 3600s 

BatteryChange: 0x01 (0.1V) 

Illuminance

 

Threshold:

   

The device samples the illumination according to the Min Interval. When the illumination exceeds the set threshold, a   

report will be sent. 

Illuminance

 

Threshold: 0x00FF (255 LUX)      // The threshold setting range is 0x0000-0x0BB8 (0~3000 LUX) 

 

Note: 

The reported data is decoded by the Netvox LoRaWAN Application Command document and   

http://loraresolver.netvoxcloud.com:8888/page/index

 

Summary of Contents for R313B

Page 1: ...document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in p...

Page 2: ...Main Features 3 4 Set up Instruction 4 5 Data Report 5 5 1 Example of ReportDataCmd 5 5 2 Example of ConfigureCmd 6 5 3 Example for MinTime MaxTime logic 7 5 4 Difference between R313B and R313G 8 6 I...

Page 3: ...spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For example automatic met...

Page 4: ...ugh third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consumption...

Page 5: ...he device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network The gre...

Page 6: ...t Change Reportable Change Current Change Reportable Change Any number between 1 65535 Any number between 1 65535 Can not be 0 Report per Min Interval Report per Max Interval When the device is powere...

Page 7: ...bytes 1 Command Configuration MinTime 1min MaxTime 1min BatteryChange 0 1v IlluminanceThreshold 200 lux Downlink 014B003C003C0100C80000 003C Hex 60 Dec C8 Hex 200 Dec Response 814B000000000000000000 C...

Page 8: ...Time duration regardless BatteryVoltageChange value Example 2 based on MinTime 15 Minutes MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime Sleeping MinTime sleeping sleeping slee...

Page 9: ...t recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no mat...

Page 10: ...ue needs to be detected please do not stick it to a rough surface to prevent the device from falling off after a long time Note 1 Wipe the surface clean before installation to avoid dust on the surfac...

Page 11: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Reviews: