10 

6. Installation 

(1) This product does not have a waterproof function. After the screening is completed, please place it indoors.   

(2) The dust at the equipment installation position needs to be wiped clean and then pasted.   

(3) The battery installation method is as shown below (the battery has a "+" side facing outward) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

 

The key ring of the portable wireless emergency Button 

(R312A) can be snapped onto the backpack, the keychain 

around the waist, or hangs around the neck with a lanyard. 

 

Note:   

Do not install the device in a metal shielded box or other 

electrical equipment around it to avoid affecting the wireless 

transmission of the device.   

The emergency button (R312A) can be applied to the 

following scenarios: 

 

Nursing home 

 

Family (bathroom) 

 

School 

 

Hospital 

 

Bank 

 

Wisdom site 

 

Wait for scenes where there is a possibility of an 

emergency.

 

2. Press and hole the emergency button for 3 seconds, the 

"alarm" message is generated.   

When the device reports data periodically, it restores the 

"normal" status and sends "normal" status information. 

 

Note: 

  When alarming, the data alarm bit is “1”;   

 

When it returns to normal, the data alarm bit is “0”.     

 

Summary of Contents for R312A

Page 1: ...This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 10 7 Important Maintenance Instruction 11...

Page 3: ...spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building aut...

Page 4: ...m Configuration parameters can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility Thi...

Page 5: ...network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on the device to search the previous network...

Page 6: ...r Max Interval The device will immediately send a version packet report along with an uplink packet including alarm status The device sends data in the default configuration before any configuration i...

Page 7: ...0000000 Configuration failure 2 Read Configuration Downlink 024D000000000000000000 Response 824D003C003C0100000000 Current configuration Description Device Cmd ID Device Type NetvoxPayLoadData Config...

Page 8: ...iguration Description CmdID PayLoad Fix byte 1byte SetButtonPressTimeReq 0x01 PressTime 1byte 0x00_QuickPush_Less then 1 Second 0x01_1 Second push 0x02_2 Seconds push 0x03_3 Seconds push 0x04_4 Second...

Page 9: ...M 1H 25th M 1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 2 8V Does not report Wakes up and collects data REPORTS 2 8V Wakes up and collects data REPORT 2 8V Wakes up and collects data REPO...

Page 10: ...ts according to MinTime interval If the data variation is not greater than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval val...

Page 11: ...neck with a lanyard Note Do not install the device in a metal shielded box or other electrical equipment around it to avoid affecting the wireless transmission of the device The emergency button R312...

Page 12: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Reviews: