7
5.3 Example of ConfigureCmd
FPort
:
0x07
Bytes
1
1
Var (Fix =9 Bytes)
CmdID
DeviceType
NetvoxPayLoadData
CmdID
– 1 byte
DeviceType
– 1 byte – Device Type of Device
NetvoxPayLoadData
– var bytes (Max=9bytes)
(1)
Command Configuration:
MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v, Acceleratedspeedchange = 1m/s²
Downlink
:
01C7003C003C0100010000 003C(H
ex)
= 60(D
ec)
Response
:
81C7000000000000000000
(
Configuration success
)
81C7010000000000000000
(
Configuration failure
)
(2)
Read Configuration:
Downlink
:
02C7000000000000000000
Response
:
82C7003C003C0100010000
(
Current configuration
)
Description Device
Cmd
ID
Device
Type
NetvoxPayLoadData
Config
ReportReq
R311FD
0x01
0xC7
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Acceleration
Change
(2byte Unit:m/s2)
Reserved
(2Bytes,Fixed
0x00)
Config
ReportRsp
0x81
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes,Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Acceleration
Change
(2byte Unit:m/s2)
Reserved
(2Bytes,Fixed
0x00)