background image

                                                             

   

 

 

 

 

 

Wireless

 

Light Sensor   

Model: R311B

 

 

 

 

 

 

 

 

 

 

Wireless Light Sensor 

 

R311B 

User Manual   

 

 

 

 

 

 

 

 

 

Copyright©Netvox Technology Co., Ltd.

 

This document contains proprietary technical information which is the property of NETVOX Technology. It shall 

be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written 

permission of NETVOX Technology. The specifications are subject to change without prior notice. 

 

 

 

Summary of Contents for R311B

Page 1: ...document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in p...

Page 2: ...Main Features 3 4 Set up Instruction 4 5 Data Report 5 5 1 Example of ReportDataCmd 5 5 2 Example of ConfigureCmd 6 5 3 Example for MinTime MaxTime logic 7 5 4 Difference between R311B and R311G 8 6 I...

Page 3: ...nication distance It can be widely used in any use case that requires long distance and low data wireless communications For example automatic meter reading building automation equipment wireless secu...

Page 4: ...ugh third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consumption...

Page 5: ...he device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network The gre...

Page 6: ...portable Change Current Change Reportable Change Any number between 1 65535 Any number between 1 65535 Can not be 0 Report per Min Interval Report per Max Interval When the device is powered on and ac...

Page 7: ...bytes 1 Command Configuration MinTime 1min MaxTime 1min BatteryChange 0 1v IlluminanceThreshold 200 lux Downlink 014B003C003C0100C80000 003C Hex 60 Dec C8 Hex 200 Dec Response 814B000000000000000000 C...

Page 8: ...Time duration regardless BatteryVoltageChange value Example 2 based on MinTime 15 Minutes MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime Sleeping MinTime sleeping sleeping slee...

Page 9: ...t recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no mat...

Page 10: ...ue needs to be detected please do not stick it to a rough surface to prevent the device from falling off after a long time Note 1 Wipe the surface clean before installation to avoid dust on the surfac...

Page 11: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...