background image

 

 

2.

 

Appearance 

           

          

 

 

3. Main Features 

 

Compatible with LoRaWAN 

 

2 sections of 3V CR2450 button battery power supply 

 

Illuminance detection 

 

Simple operation and setting 

 

Protection level IP30 

 

Compatible with LoRaWAN

TM

 Class A 

 

Frequency hopping spread spectrum technology 

 

Configuration parameters can be configured through third-party software platforms, data can be read and alarms can be set via 

SMS text and email (optional) 

 

Available third-party platform: Actility / ThingPark, TTN, MyDevices/Cayenne 

 

Low power consumption and long battery life 

Note*:   

Battery life is determined by the sensor reporting frequency and other variables, please refer to 

http://www.netvox.com.tw/electric/electric_calc.html

 On this website, users can find battery life time for varied models at 

different configurations. 

 

 

Indicator 

 

Light Sensor 

Function Key

 

Summary of Contents for R311B

Page 1: ...document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in p...

Page 2: ...Main Features 3 4 Set up Instruction 4 5 Data Report 5 5 1 Example of ReportDataCmd 5 5 2 Example of ConfigureCmd 6 5 3 Example for MinTime MaxTime logic 7 5 4 Difference between R311B and R311G 8 6 I...

Page 3: ...nication distance It can be widely used in any use case that requires long distance and low data wireless communications For example automatic meter reading building automation equipment wireless secu...

Page 4: ...ugh third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consumption...

Page 5: ...he device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network The gre...

Page 6: ...portable Change Current Change Reportable Change Any number between 1 65535 Any number between 1 65535 Can not be 0 Report per Min Interval Report per Max Interval When the device is powered on and ac...

Page 7: ...bytes 1 Command Configuration MinTime 1min MaxTime 1min BatteryChange 0 1v IlluminanceThreshold 200 lux Downlink 014B003C003C0100C80000 003C Hex 60 Dec C8 Hex 200 Dec Response 814B000000000000000000 C...

Page 8: ...Time duration regardless BatteryVoltageChange value Example 2 based on MinTime 15 Minutes MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime Sleeping MinTime sleeping sleeping slee...

Page 9: ...t recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no mat...

Page 10: ...ue needs to be detected please do not stick it to a rough surface to prevent the device from falling off after a long time Note 1 Wipe the surface clean before installation to avoid dust on the surfac...

Page 11: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Reviews: