7. TROUBLESHOOTING
SYMPTOM
INSPECTION
SOLUTION
The unit is not
operating.
Check the power connection in securely.
Insert the power cord securely into the
wall Outlet.
Check if the water level indicator lights
up?
Empty the water tank and reinstall
correctly.
Check the room temperature.
The range of operating temperature is
5-35
℃
.
There is little
formation of
condensate.
Check the air filter for dirt.
Clean the air filter as necessary.
Check if the air duct is blocked.
To clear the obstacle.
Check if the room temperature is below
20
℃
.
This is normal. Low humidity in low
temperature environment.
Set humidity level is higher than
current Humidity value.
Set the humidity level below current
humidity value.
Water Leakage
Overflow while moving the unit.
Empty the water tank before transport.
Check if the drain hose is kinked or
bends.
Straighten the hose to avoid a trap
existing.
Excessive Noise
Check if the unit is securely positioned.
Place the unit on horizontal and firm
ground.
Check if any loose, vibrating parts.
Secure and tight the parts.
Noise sounds like water flowing.
Noise comes from flowing refrigerant.
This is normal.
ERROR
CODES
E1
Humidity sensor dampened or failure.
To clean or replace the humidity sensor.
CL
Display when Room temperature is
below 5°C
(
41°F
)
.
Normal. The compressor stops, and the
fan keeps running.
CH
Display when Room temperature is
above35
℃(
95°F
)
.
Normal. The compressor stops, and the
fan keeps running.
LO
Display when Room relative humidity is
bellow 20%RH.
Normal. The compressor stops, and the
fan keeps running.
HI
Display when Room relative humidity is
above 95%RH.
Normal. The compressor and the fan
keep running.