13
F.
Water FULL Indicator
The machine automatically shuts off once the water tank is full, alerting the user through an indicator
light and buzzing for 15 times. It reminds you to check:
If the water tank is full, empty and re-install the water tank.
If the water tank is not in position, the full indicator always on and the unit is inoperative.
Re-install the tank correctly, and the unit will auto operating as your last setting.
G.
Auto Restart function
When there is a power outage, the dehumidifier automatically restarts when the power comes back on
and also resumes settings.
H.
Automatic Defrost function
At low room temperatures (below 18
℃
), frost may buildup at the evaporator reducing the airflow across
it during dehumidifying.
The dehumidifier will automatically start defrosting for 7 minutes.
The POWER LED blinking.
The compressor stops and the fan keeps running.
Do not turn off the unit and it will automatically restart dehumidifying.
I.
Overload Protection
In the event of a power loss, to protect the compressor there is a 3-minute delay until the compressor
restarting.