Checks to Electrical Devices
Repair and maintenance to electrical components shall include initial
safety checks and component inspection procedures. If a fault exists
that could compromise safety, then no electrical supply shall be
connected to the circuit until it is satisfactorily dealt with. If the fault
cannot be corrected immediately but it is necessary to continue
operation, an adequate temporary solution shall be used. This shall be
reported to the owner of the equipment, so all parties are advised.
Initial safety checks shall include:
-
The capacitors are discharged. This shall be done in a safe
manner to avoid possibility of sparking.
-
That there are no exposed live electrical components or wires
while charging, recovering, or purging the system.
-
That there is continuity of earth bonding.
WARNING!
Install the unit in rooms which exceed 10 m².
Do not install the unit in a place where inflammable gas may
leak.
NOTE!
The manufacture may provide other suitable example or may
provide additional information about the refrigerant odour.
Summary of Contents for 103893
Page 14: ...Remote Control...