Automatic Defrost
•
At low room temperatures, frost may build-up in the
evaporator during operation. The unit will automatically start
defrosting and the ‘POWER’ LED will start blinking. The
defrost control sequence is as follows:
•
A. When the unit operates
in ‘COOL’ mode, the ambient
temperature sensor will sense when the evaporator coil
temperature is below -1°C. After this, the compressor will stop
operating for 10 minutes or until the coil temperature rises by
7
℃
, then the unit will return to the ‘COOL’ operating mode.
•
B. When the unit operates in ‘DRY’ mode, the coil
temperature sensor will sense when the temperature of the
evaporator is below 40
℃
and the differential temperature
between the coil and the room is below 19
℃
. The unit will
then start defros
ting for 5 minutes and the ‘POWER’ LED will
start blinking.
Drainage
•
The self-evaporating system uses the collected water to cool
the condenser coils for a more efficient performance. There is
no need to empty the drainage tank in ‘COOL’ mode. Only in
‘DRY’ mode or in high-humidity conditions. The condensed
water evaporates at the condenser and evacuated through
the exhaust hose.
•
For continuous operation or unattended operation (in ‘DRY’ or
‘HEAT’ mode), please connect the attached drain hose to the
unit. Condensed water can automatically flow into a bucket or
drain.
(See next page for how to install the drain hose).