NVF-2400S 4 Band VDSL 24 Ports Managed IP DSLAM USER’S MANUAL Ver_A.8
19
Chapter 3.
Complete Installation
3.1 Hardware Installation
This chapter describes how to install the NVF-2400S to establish network connection. You may install the IP DSLAM
on any level surface (table, shelf, 19 inch rack or wall mounting). However, please take note of the following minimum
site requirements before you begin.
3.2 Pre-installation Requirements
Before you start actual hardware installation, make sure you can provide the right operating environment, including
power requirements, sufficient physical space, and proximity to other network devices that are to be connected. Verify
the following installation requirement:
Verify the following installation requirements:
Power requirements: AC 100V to 240 V at 50 to 60 Hz.
Tip:
The Switching power supply automatically adjusts to the input voltage level.
The IP DSLAM should be located in a cool dry place, with at least 10cm/4in of space at the front and back for ventilation
Place the
NVF-2400S
away from direct sunlight, heat sources, or areas with a high amount of electromagnetic
interference.
Check if network cables and connectors needed for installation are available
Do Not install phone lines strapped together with AC power lines, or telephone office line with voice signal.
Avoid installing this device with radio amplifying station nearby or transformer station nearby.
Please note NVF-2400S internal splitter, can pass through voice spectrum is 0KHz ~ 630KHz.