NV-202M/S LAN extender with Remote Power
USER’S MANUAL Ver. A.2
8
•
Power requirements:
1 x 48VDC /
1.875A or above
•
NV-202M/S should be located in a cool dry place with at least
10cm / 4in
of space at the front and back for
ventilation.
•
Place NV-202M/S away from direct sunlight, heat sources, or areas with a high amount of electromagnetic
interference.
•
Check if the network cables and connectors needed for installation are available.
•
Do Not
install phone lines strapped together with AC power lines, or telephone office line with voice signal.
•
Do Not
install phone lines with POTS/ISDN.
•
Avoid installing this device with radio amplifying station nearby or transformer station nearby.
•
Please connecting FG of NV-202M and NV-202S on rear panel to earth ground.
2.3 General Rules
Before making any connections to the NV-202M/S, please note the following rules:
•
Ethernet Port (RJ45)
All network connections to the NV-202M/S Ethernet port must be made using Category 5 UTP for 100Mbps,
Category 3, 4 UTP for 10Mbps.
No more than 100 meters of cabling may be used between the MUX or HUB and an end node.
•
Line Port (RJ-11 / Terminal block)
All Home network connections to the line port must use single pair
22~26
gauge with twisted pair phone
wiring. RJ-11 and terminal block is shared and cannot be used together at the same time.
•
We
do not
recommend using
28 gauge
or above phone line.
•
Please note that the line port support reverse polarity protection, when user install the phone wire and
reverse the two wires, it could be used.