- 65 -
UPS Type
Select UPS Type. Choose Smart-UPS for APC, None
for other vendors or no UPS.
Shutdown
Battery Level
(%)
When below the setting level, system will shutdown.
Setting level to
“0”
will disable UPS.
Shutdown
Delay (s)
If power failure occurred, and system can not return
to value setting status, the system will shutdown.
Setting delay to
“0”
will disable the function.
Shutdown
UPS
Select ON, when power is gone, UPS will shutdown
by itself after the system shutdown successfully. After
power comes back, UPS will start working and notify
system to boot up. OFF will not.
Status
The status of UPS.
“Detecting…”
“Running”
“Unable to detect UPS”
“Communication lost”
“UPS reboot in progress”
“UPS shutdown in progress”
“Batteries failed. Please change them NOW!”
Battery Level
(%)
Current percentage of battery level.
3.8 System maintenance
“Maintenance”
allows operation of the system functions including
“Upgrade”
to the latest firmware,
“Info”
to show the system version,
“Reset to default
”
to reset all controller configuration values to factory settings,
“Config import
& export”
to import and export all controller configuration except VG/UDV
setting and LUN setting, and
“Shutdown”
to either reboot or shutdown the