[SMS] Sockets and Indication Elements
–
•
•
•
•
GSM ANT Socket
A
GSM
ANT
socket is designed for connecting an external GSM antenna to a device.
LAN Socket
An Ethernet 10/100 BASE-T port is used for connecting to a network.
An Ethernet port has two LEDs. The left one –
CPU,
when lighting, it means a device is turned on and when blinking
it means transferring packages to a network. The right one –
Link,
when lighting it means having a link on the port,
and when blinking, it means receiving packages from a network.
EXT BAT STATUS Terminal Block
A
EXT BAT
STATUS
terminal block is designed to connect IO
STATE
lines of a NetPing mini-UPS device.
Terminal 1 –. GND
Terminal 2 – IO Line 2
Terminal 3 – IO Line 1
Logic level 0 – no more than 0.3 V. Logic level 1 – no more than 0.7 V. A maximum allowable voltage is 5 V.
Electric parameters of IO lines
In the «output» mode:
the voltage of logic «1»: mai3,3V 2mA (is not used as the output);
the voltage of logic «0»: maintains 0 V, 2 mA (is not used as the output).
In the «input» mode:
voltage of logic «1»: > 2,31 V;
voltage of logic «0»: < 0,99 V.
The functionality of this terminal block is not implemented in the firmware of the device, so in practice it
cannot yet be used.