Page 2: ...5 2 1 Configuration of network parameters 12 5 2 2 E mail configuration 14 5 2 3 Time settings 14 5 2 4 Serial tunnel model NETIO 230CS 15 5 2 5 Configuration of user accounts 16 5 2 6 Firmware update...

Page 3: ...nfiguration of port parameters 10 5 3 Configuration of output 11 5 4 Configuration of the network 13 5 5 E mail configuration 14 5 6 Setting the date and time 15 5 7 Serial tunnel symbol on the front...

Page 4: ...Installation Guide which is included in the pack You thus forego erroneous installation or incorrect usage of the device Carefully read the following notice The device that you have purchased operates...

Page 5: ...ironment with strong vibrations 4 If the device malfunctions contact your vendor 5 Unauthorised modification of this device can damage it or cause fire 6 Prevent contact with fluids do not expose the...

Page 6: ...a timer control the power supply to your electrical appliances such as computers servers routers electric gates security surveillance system or any appliance 1 1 Characteristics Integrated web server...

Page 7: ...y voltage 90 250 V AC Maximum switching current 10 A Dimensions 220 40 125 mm w h d Network interface 1x RJ 45 10 100 Mbit s NETIO 230C 1x CANON DB9 F RS232 NETIO 230CS 2x CANON DB9 F RS232 1 3 Minimu...

Page 8: ...2 1 Front view NETIO 230C Figure 2 1 NETIO 230C front view 1 Four indicator led diodes 2 Manual buttons for switching outputs on off 3 Serial port RS232 4 Connector RJ 45 network interface for connect...

Page 9: ...w NETIO 230CS Figure 2 2 NETIO 230CS front view 1 Four indicator led diodes 2 Manual buttons for switching outputs on off 3 Serial port RS232 4 Connector RJ 45 network interface for connection to Ethe...

Page 10: ...Equipment interface 5 2 3 Back view NETIO 230C CS Figure 2 3 NETIO 230C CS back view 1 Main Switch 2 Power supply 90 250 VAC 3 Fuse holder for main fuse 4 Controlled power supply outputs...

Page 11: ...nnection of the device 1 Connect the NETIO 230C CS to the network switches router using the network cable with the RJ 45 connectors 2 Connect the NETIO power supply cable to the plug 3 Connect the dev...

Page 12: ...the button Discover This lists all the accessible NETIO device in your network 3 Select the device from the list and then click the button Device setup Figure 4 1 Devices found The parameters configu...

Page 13: ...if you do not have a DHCP server in the network If you have the device gets the address from the DHCP server 4 You access the web interface of the device either by entering the IP address into the In...

Page 14: ...ly The port is deactivated for the period set in the menu Status configuration in the field Interrupt delay and then restarted Short term interruption of the port can be used only on an active port If...

Page 15: ...rs To set a specific port select the desired port in the column Select and click the button Modify On the page that subsequently opens you can set the detailed parameters of the selected port The impo...

Page 16: ...g on the device if you select the field the port is activated after start or restart of the device Manual control makes possible manual control of the port deactivates automatic timer control This cho...

Page 17: ...maximum number of restart attempts for a given port Enable activation of watchdog function IP address IP address of the network device to be monitored Timeout maximum response time of the monitored de...

Page 18: ...rmines the period between triggering two outputs This delay is set to protect the device from overload upon switching on all outputs simultaneously KSHELL Port WEB Port makes it possible to change the...

Page 19: ...Figure 5 5 E mail configuration From this address shall be shown in the message as the sender s address To the message shall be sent to this address SMTP server mail server via which the message shall...

Page 20: ...start Daylight saving time end date and time of summer time end Local time manual setting of local time with deactivated synchronisation with SNTP server Setting of the summer time and local time offs...

Page 21: ...s ignore To secure access to the serial tunnel it is possible to activate the IP filter function In the following fields it is then possible to set the computer from which it will be possible to conne...

Page 22: ...the following categories Add add a new user Modify change the password and user authorisation of a selected user Remove remove selected user 5 2 6 Firmware update The Firmware Update page is used to...

Page 23: ...work with the new firmware version Figure 5 12 Call to download new firmware file 5 3 Control of the device via Telnet CGI or serial link 5 3 1 Encrypted login For login with secure password you must...

Page 24: ...ry relay of communication via KSHELL interface has limited validity In case of inactivity of approximate duration one minute the relay shall be terminated automatically If you need to keep the relay a...

Page 25: ...changed Example The command port list 01ui deactivates port 1 activates port 2 leaves port 3 unchanged and interrupts port 4 port setup output output_name mod manual timer interrupt_delay PON_status C...

Page 26: ...port wd 4 enable activates the watchdog function on port 4 port wd output wd enable disable wd_ip_addr wd_timeout wd_PON_delay ping_interval max_retry max_retry_poff enable disable send_email enable...

Page 27: ...l ip_address mask gateway Sets the network interface IP address network mask and gateway are set only if the manual parameter is selected For the changes to take effect it is necessary to either resta...

Page 28: ...Lists the time offset from UTC for local time The value is listed in seconds system reset Reset device to factory settings After posting this command the factory setting is restored and the system re...

Page 29: ...return value is html 110 BYE html This command can be used only in CGI compatible mode with older devices port list xxxx The parameter list lists the output state in the format html port1 port2 port3...

Page 30: ...ash Device response after connection Hash after HELLO can be used for encrypted login 110 BYE You have been logged off 120 Rebooting Restarting 130 CONNECTION TIMEOUT Connection time out 250 OK Comman...

Page 31: ...n If any of the concerned diodes is not green this specific output is off The red LED diodes inform the user about different states of the entire device The following states are possible Red LED 1 is...

Page 32: ...R SUPPLY Also disconnect all the devices connected to the outputs To replace the fuse unscrew the fuse holder ideally using a flat screwdriver Always replace the fuse with a new fuse of same type 250V...

Page 33: ...unprofessional activities of third parties outside the manufacturer s authorized service shop We believe that you will be satisfied with our product In case of any questions or comments relating to th...