NETGEAR FSM7352PS - ProSafe 48 Port 10/100 L3 Managed Stackable Switch Installation Manual Download Page 1

Page 1 of 24 

© 2005 by NETGEAR, Inc. All rights reserved. 

Trademarks 

© 2005 NETGEAR, Inc. NETGEAR ® ,  the Netgear Logo, the Gear Guy, and Everybody’s connecting are trademarks or registered trademark of 
Netgear, Inc. in the United States and/or other countries. Microsoft, Windows, and the Windows logo are trademarks, or registered   trademarks of 
Microsoft Corporation in the United States and/or other countries. Other brand and Product names are trademarks or registered trademarks of their 
respective holders. Information is subject to change without notice. All rights reserved. 

 

Statement of Conditions 

In the interest of improving internal design, operational function, and/or reliability, NETGEAR reserves the right to make changes to the products 
described in this document without notice. NETGEAR does not assume any liability that may occur due to the use or application of the product(s) or 
circuit layout(s) described herein. 

 

Certificate of the Manufacturer/Importer 

It is hereby certified that the NETGEAR Model  FSM7352PS ProSafe 48+4 Fast Ethernet L3 Managed Stackable Switch with PoE has been 
suppressed in accordance with the conditions set out in the BMPT-AmtsblVfg 243/1991 and Vfg 46/1992.The operation of some equipment (for 
example, test transmitters) in accordance with the regulations may, however, be subject to certain restrictions. Please refer to the notes in the 
operating instructions.  

Federal Office for Telecommunications Approvals has been notified of the placing of this equipment on the market and has been granted the right 
to test the series for compliance with the regulations. 

 

Voluntary Control Council for Interference (VCCI) Statement 

This equipment is in the first category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set 
by the Voluntary Control Council for Interference by Data Processing Equipment and Electronic Office Machines that are aimed at preventing radio 
interference in commercial and/or industrial areas. 

Consequently, when this equipment is used in a residential area or in an adjacent area thereto, radio interference may be caused to equipment 
such as radios and TV receivers. 

 

Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 

This device may not cause harmful interference. 

This device must accept any interference received, including interference that may cause undesired operation. 

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and 
can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct 
the interference by one or more of the following measures: 

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and receiver. 

Connect the equipment into an outlet on a circuit different from that which the receiver is connected. 

Consult the dealer or an experienced radio/TV technician for help. 

 

EN 55 022 Declaration of Conformance 

This is to certify that the NETGEAR Model  FSM7352PS ProSafe 48+4 Fast Ethernet L3 Managed Stackable Switch with PoE is shielded against 
the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the 
application of EN 55024 Class A (CISPR 22).  

EN 55 022 and EN 55 024 Statements 

This is to certify that the NETGEAR Model  FSM7352PS ProSafe 48+4 Fast Ethernet L3 Managed Stackable Switch with PoE is shielded against 
the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the 
application of EN 55 022 Class A (CISPR 22) and EN 55 024. 
 

Summary of Contents for FSM7352PS - ProSafe 48 Port 10/100 L3 Managed Stackable Switch

Page 1: ...rea or in an adjacent area thereto radio interference may be caused to equipment such as radios and TV receivers Federal Communications Commission FCC Compliance Notice Radio Frequency Notice This dev...

Page 2: ...de bruits radio lectriques visant les appareils num riques de classe A prescrites dans le R glement sur le brouillage radio lectrique du minist re des Communications du Canada Customer Support For as...

Page 3: ...nstalling the Switch 14 Step 3 Checking the Installation 14 Step 4 Applying AC Power 14 Step 5 Connecting Devices to the Switch 15 Step 6 Installing a SFP Module 15 Step 7 Connecting to the Console Po...

Page 4: ...STACKABLE SWITCH WITH POE 9 FIGURE 2 3 WARNING CREATING REDUNDANT PATHS BETWEEN NETWORK DEVICES 10 FIGURE 3 1 ATTACHING MOUNTING BRACKETS 14 FIGURE 3 2 CONNECTING DEVICES TO THE SWITCH 15 FIGURE 3 3...

Page 5: ...SNMP and RMON for port and switch information VLAN for traffic control port trunking for increased bandwidth and Class of Service CoS for traffic prioritization These features and more will allow you...

Page 6: ...3z 1000BASE X o IEEE 802 3x full duplex flow control Full Layer 2 switch management including o SNMP v1 v2c v3 o RMON groups 1 2 3 and 9 o IEEE 802 1Q up to 512 Static VLAN groups o IEEE 802 1D Spanni...

Page 7: ...sing and auto negotiating speed o Auto Uplink on all ports to automatically make the right connection MDI MDI X o Full and half duplex functions Automatic address learning function to build the packet...

Page 8: ...the 4 SFP sockets Power cord Null modem console cable Rack mount kit for installing the switch in a 19 inch rack Quick Installation Guide Product CD ROM ProSafe NMS100 Network Management System 30 da...

Page 9: ...ProSafe 48 4 Fast Ethernet L3 Managed Stackable Switch with PoE 10 100 1000 Mbps RJ 45 Ports As Figures 2 1 and 2 3 shows the FSM7352PS ProSafe 48 4 Fast Ethernet L3 Managed Stackable Switch with PoE...

Page 10: ...ink technology eliminates the need for setting uplink connections or being concerned about whether to use crossover or straight through cables when attaching devices Figure 2 3 Warning Creating Redund...

Page 11: ...Blinking Yellow Indicates the PoE MAX LED was active in the previous two minutes Off There is at least 7W of PoE power available for another device RPS Solid Green RPS Bank supply POE power Off RPS Ba...

Page 12: ...ink is present or not Console Port Your NETGEAR Model FSM7352PS ProSafe 48 4 Fast Ethernet L3 Managed Stackable Switch with PoE has a console port on the front panel This port is labeled Console and i...

Page 13: ...ess Locate the switch in a position that lets you access the front panel RJ 45 ports view the front panel LEDs and access the rear panel power connector Power source Provide a power source within 6 fe...

Page 14: ...e side of the switch 2 Insert the screws provided in the rack mount kit through each bracket and into the bracket mounting holes in the switch 3 Tighten the screws with a 1 Phillips screwdriver to sec...

Page 15: ...does not resolve the problem refer to Appendix B Troubleshooting Step 5 Connecting Devices to the Switch The following procedure describes how to connect devices to the switch s network RJ 45 ports Yo...

Page 16: ...o connect a console to the switch 1 Connect a VT100 ANSI terminal or a PC Apple Macintosh or UNIX workstation to the switch s console port labeled Console using the null modem cable supplied with the...

Page 17: ...switch is shipped with DHCP as default to receive its IP address to manually set a static IP address for the management VLAN you must first disable DHCP as follows FSM7352PS en Password just hit enter...

Page 18: ...lt using DHCP mode to assign its address If you leave the switch IP mode in the default DHCP mode the IP address of your switch could change and you would have to reconnect to the switch via the conso...

Page 19: ...witch with PoE has a redundant power supply connector in the back You may choose to connect a DC to DC power supply to the switch to ensure that it will not fail in case the primary power supply does...

Page 20: ...Tree Protocol STP IEEE 802 1w Rapid Spanning Tree Protocol RSTP IEEE 802 1s Multiple Spanning Tree Protocol MSTP IEEE802 3ad Link Aggregation LACP IGMP v1 v2 Snooping Support Layer 3 Services VLAN ro...

Page 21: ...in store and forward mode for10 Mbps to 100 Mbps transmission Address database size 16 384 media access control MAC addresses per system Addressing 48 bit MAC address 10 100 1000 buffer memory 32MB e...

Page 22: ...Page 22 of 24 VCCI Class A EN 55022 CISPR 22 Class A C Tick Electromagnetic Immunity EN 50082 1 EN 55024 Safety CE mark commercial CSA certified CSA 22 2 950 UL listed UL 1950 cUL IEC950 EN60950...

Page 23: ...g them in an alternate environment where all products are functioning File transfer is slow or performance degradation is a problem Half or full duplex setting on the switch and the connected device a...

Page 24: ...from the switch and then reapply AC power If the problem continues contact NETGEAR technical support In North America call 1 888 NETGEAR If you are outside of North America please refer to the support...

Page 25: ...ssword protection Disabled User Name Admin Password None Web Access Enabled Java Mode Enabled VLAN All ports belong to Default VLAN VLAN 1 as untagged ports IP Multicast Filtering Disabled Spanning Tr...

Reviews: