NETGEAR FS726TP - ProSafe Smart Switch Hardware Installation Manual Download Page 3

Page 3 of 19 

 

Canadian Department of Communications Radio Interference Regulations

 

This digital apparatus (NETGEAR ProSafe FS726TP Smart Switch with PoE) do not exceed the Class A limits for radio-noise emissions from digital 
apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications.

 

 

Règlement sur le brouillage radioélectrique du ministère des Communications

 

Cet appareil numérique (NETGEAR ProSafe FS726TP Smart Switch with PoE) respecte les limites de bruits radioélectriques visant les appareils 
numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique du ministère des Communications du Canada.

 

 

Customer Support

 

For assistance with installing and configuring your NETGEAR system or with questions or problems following installation: 

 

Check the NETGEAR Web page at http://www.NETGEAR.com/support 

 

Call Technical Support in North America at 1-888-NETGEAR. If you are outside North America, please refer to the phone numbers listed 
on the Support Information Card that shipped with your switch. 

 

Email Technical Support at [email protected]

Defective or damaged merchandise can be returned to your point-of-purchase representative.

 

 

Internet/World Wide Web

 

NETGEAR maintains a World Wide Web home page that you can access at the uniform resource locator (URL) http://www.NETGEAR.com. A 
direct connection to the Internet and a Web browser such as Internet Explorer or Netscape are required.

 

 
 

Summary of Contents for FS726TP - ProSafe Smart Switch

Page 1: ...June 2005 NETGEAR Inc 4500 Great America Parkway Santa Clara CA 95054 USA Phone 1 888 NETGEAR FS726TP Hardware Installation Manual ...

Page 2: ...o Frequency Notice This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions This device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 o...

Page 3: ...que du ministère des Communications du Canada Customer Support For assistance with installing and configuring your NETGEAR system or with questions or problems following installation Check the NETGEAR Web page at http www NETGEAR com support Call Technical Support in North America at 1 888 NETGEAR If you are outside North America please refer to the phone numbers listed on the Support Information ...

Page 4: ...UTTON 11 STEP 1 PREPARING THE SITE 12 STEP 2 INSTALLING THE SWITCH 12 STEP 3 CHECKING THE INSTALLATION 13 STEP 4 CONNECTING DEVICES TO THE SWITCH 13 STEP 5 INSTALLING AN SFP GBIC MODULE 13 STEP 6 APPLYING AC POWER 14 STEP 7 SWITCH MANAGEMENT THROUGH A WEB BROWSER OR THE PC UTILITY FOR INITIAL CONFIGURATION 14 TROUBLESHOOTING CHART 17 ADDITIONAL TROUBLESHOOTING SUGGESTIONS 17 ...

Page 5: ... the NETGEAR ProSafe FS726TP Smart Switch with PoE 9 Figure 3 1 Example of Desktop Switching 12 Figure 4 1 Attaching Mounting Brackets 13 Figure 4 2 Connecting Devices to the Switch 13 Figure 4 3 Installing a Gigabit Ethernet Module into FS726TP 14 Tables Table 2 1 Front Panel LEDs 10 Table 4 1 Site Requirements 12 Table B 1 Troubleshooting Chart 17 ...

Page 6: ...high speed connections to a server or network backbone For example you can Connect switches to each other with high speed links Link to high speed servers Provide 10 100 1000 copper and fiber connectivity Your NETGEAR ProSafe FS726TP Smart Switch with PoE also provides the benefit of administrative management with a complete package of features for the observation configuration and control of your...

Page 7: ...o Discovery application program for discovering and managing the switches on the network Support flash upgrading configuration backup restore and factory reset Full compatibility with IEEE standards IEEE 802 3i 10BASE T IEEE 802 3u 100BASE TX IEEE 802 3z ab 1000BASE X 1000Base T IEEE 802 3af Power over Ethernet IEEE 802 3x full duplex flow control Auto sensing and auto negotiating capabilities for...

Page 8: ...ains the following NETGEAR ProSafe FS726TP Smart Switch with PoE Rubber footpads for tabletop installation Power cord Rack mount kit for installing the switch in a 19 inch rack Installation guide Smart Switch Resource CD with Smart Wizard Discovery and User s manual Warranty Support Information Card If any item is missing or damaged contact your place of purchase immediately ...

Page 9: ...f the attached device All ports support only unshielded twisted pair UTP cable terminated with an 8 pin RJ 45 plug To simplify the procedure for attaching devices all RJ 45 ports support Auto Uplink This technology lets you attach devices to the RJ 45 ports either straight through or crossover cables When you insert a cable into the switch s RJ 45 port the switch automatically Senses whether the c...

Page 10: ...other device 10 100M Ports Link ACT 100M z Solid Green A valid 10 100Mbps link is established on the port z Blinking Green Packets transmission or reception is occurring on the port at 100Mbps z OFF No 10 100Mbps link is established on the port z Solid Green A valid 100Mbps link is established on the port z OFF No 10Mbps link is established on the port PoE Ports ports 1 to 12 POE POE fault z Solid...

Page 11: ... insert a small device such as a paper clip into the opening to press the recessed button The LEDs on the switch should go out and then come back on as the switch goes through its Power On Switch Test POST Factory Defaults Button The FS726TP has a Factory Default Button to enable you to clear out the current configuration and return to the factory settings This will clear out all settings includin...

Page 12: ...air exhausts hot air vents and heaters Operating humidity The installation location should have a maximum relative humidity of 90 non condensing Ventilation Do not restrict airflow by covering or obstructing air inlets on the sides of the switch Keep at least 2 inches 5 08 centimeters free on all sides for cooling Be sure there is adequate airflow in the room or wiring closet where you intend to i...

Page 13: ... crossover cables Figure 4 2 Connecting Devices to the Switch Connect each device to an RJ 45 network port on the switch s front panel see Figure 4 4 Use Category 5 Cat5 unshielded twisted pair UTP cable terminated with an RJ 45 connector to make these connections Note Ethernet specifications limit the cable length between the switch and the attached device to 100 m 328 ft Step 5 Installing an SFP...

Page 14: ...Power LED does not go on check that the power cable is plugged in correctly and that the power source is good If this does not resolve the problem refer to Appendix B Troubleshooting Step 7 Switch Management through a Web Browser or the PC Utility for Initial Configuration Your NETGEAR ProSafe FS726TP Smart Switch with PoE contains software for viewing changing and monitoring the way it works This...

Page 15: ... connections such as those associated with switch ports that are experiencing congestion or failure or exceeding an administrator defined threshold Forwarding The process of sending a packet toward its destination using a networking device Filtering The process of screening a packet for certain characteristics such as source address destination address or protocol Filtering is used to determine wh...

Page 16: ... paths ensuring that only one route exists between any two LANs Spanning Tree Protocol STP A protocol that finds the most efficient path between segments of a multi looped bridged network STP allows redundant switches and bridges to be used for network resilience without the broadcast storms associated with looping If a switch or bridge falls a new path to a redundant switch or bridge is opened Sw...

Page 17: ...ected ACT LED is flashing continuously on all connected ports and the network is disabled A network loop redundant path has been created see Figure 2 3 Break the loop by ensuring that there is only one path from any networked device to any other networked device Additional Troubleshooting Suggestions If the suggestions in Table B 1 do not resolve your problem refer to the troubleshooting suggestio...

Page 18: ...e Specifications Forwarding modes Store and forward Bandwidth 8 8 Gbps Network latency Less than 20 microseconds for 64 byte frames in store and forward mode for 100 Mbps to 100 Mbps transmission Buffer memory 256 KB embedded memory per unit Address database size 8 000 media access control MAC addresses per system Mean Time Between Failure MTBF 300 000 hours 34 years Power Supply 5VDC 6A 48VDC 100...

Page 19: ...Page19of19 Modules AGM731F 1000BASE SX SFP GBIC for multimode fiber AGM732F 1000BASE LX SFP GBIC for single mode fiber AGM733 1000Base ZX SFP GBIC for long distance single mode fiber ...

Reviews: