 CHAPTER 3: INSTALLATION 

This chapter describes the installation procedures for your NETGEAR ProSafe FS726TP Smart Switch with PoE. Switch installation involves the 
following steps: 

Step 1: Preparing the site 

Step 2: Installing the switch  

Step 3: Checking the installation 

Step 4: Connecting devices to the switch 

Step 5: Installing an SFP GBIC module 

Step 6: Apply AC power 

Step 7: Switch management through a Web Brower or the PC Utility for initial configuration 

Step 1: Preparing the Site 

Before you install your switch, be sure your operating environment meets the operating environment requirements in Table 4-1.  

Table 4-1. Site Requirements

 

Characteristics 

 

Requirements

 

Mounting 

 

Desktop installations:

 

Rack-mount installations:

 

Provide a flat table or shelf surface. 
Use a 17-inch (48.3-centimeter) EIA standard equipment rack that is grounded and physically 
secure. You also need the rack-mount kit supplied with your switch.

 

Access

 

Locate the switch in a position that lets you access the front panel RJ-45 ports, view the front 
panel LEDs, and access power connector. 

Power source 

Provide a power source within 6 feet (1.8 meters) of the installation location. Power specifications 
for the switch are shown in Appendix C. Be sure the AC outlet is not controlled by a wall switch, 
which can accidentally turn off power to the outlet and the switch. 

Environmental 

 

Temperature: 

Install the switch in a dry area, with ambient temperature between 0 and 40ºC (32 and 104ºF). 
Keep the switch away from heat sources such as direct sunlight, warm air exhausts, hot-air vents, 
and heaters. 

Operating humidity: 

The installation location should have a maximum relative humidity of 90%, non-condensing. 

Ventilation: 

Do not restrict airflow by covering or obstructing air inlets on the sides of the switch. Keep at least 
2 inches (5.08 centimeters) free on all sides for cooling. 
Be sure there is adequate airflow in the room or wiring closet where you intend to install the 
switch. 

Operating conditions: 

Keep the switch at least 6 ft (1.83 m) away from nearest source of electromagnetic noise, such as 
a photocopy machine. 

 

Step 2: Installing the Switch 

You can install your NETGEAR ProSafe FS726TP Smart Switch with PoE on a flat surface or in a standard 19-inch rack. 
 

Installing the Switch on a Flat Surface 

The switch ships with four self-adhesive rubber footpads. Stick one rubber foot pad on each of the four concave spaces on the bottom of the switch. 
The rubber footpads cushion the switch against shock/vibrations. They also provide space between each stacked switch for ventilation. 
 

Installing the Switch in a Rack 

To install the switch in a rack, use the following procedure (and refer to Figure 4-1). To perform this procedure, you need the 19-inch rack-mount kit 
supplied with your switch. 

1. 

Attach the supplied mounting brackets to the side of the switch.  

2. 

Insert the screws provided in the rack-mount kit through each bracket and into the bracket mounting holes in the switch.  

3. 

Tighten the screws with a #1 Phillips screwdriver to secure each bracket.  

4. 

Align the mounting holes in the brackets with the holes in the rack, and insert two pan-head screws with nylon washers through each bracket 
and into the rack.  

5. 

Tighten the screws with a #2 Phillips screwdriver to secure the switch in the rack. 

 

 

Summary of Contents for FS726TP - ProSafe Smart Switch

Page 1: ...June 2005 NETGEAR Inc 4500 Great America Parkway Santa Clara CA 95054 USA Phone 1 888 NETGEAR FS726TP Hardware Installation Manual ...

Page 2: ...o Frequency Notice This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions This device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 o...

Page 3: ...que du ministère des Communications du Canada Customer Support For assistance with installing and configuring your NETGEAR system or with questions or problems following installation Check the NETGEAR Web page at http www NETGEAR com support Call Technical Support in North America at 1 888 NETGEAR If you are outside North America please refer to the phone numbers listed on the Support Information ...

Page 4: ...UTTON 11 STEP 1 PREPARING THE SITE 12 STEP 2 INSTALLING THE SWITCH 12 STEP 3 CHECKING THE INSTALLATION 13 STEP 4 CONNECTING DEVICES TO THE SWITCH 13 STEP 5 INSTALLING AN SFP GBIC MODULE 13 STEP 6 APPLYING AC POWER 14 STEP 7 SWITCH MANAGEMENT THROUGH A WEB BROWSER OR THE PC UTILITY FOR INITIAL CONFIGURATION 14 TROUBLESHOOTING CHART 17 ADDITIONAL TROUBLESHOOTING SUGGESTIONS 17 ...

Page 5: ... the NETGEAR ProSafe FS726TP Smart Switch with PoE 9 Figure 3 1 Example of Desktop Switching 12 Figure 4 1 Attaching Mounting Brackets 13 Figure 4 2 Connecting Devices to the Switch 13 Figure 4 3 Installing a Gigabit Ethernet Module into FS726TP 14 Tables Table 2 1 Front Panel LEDs 10 Table 4 1 Site Requirements 12 Table B 1 Troubleshooting Chart 17 ...

Page 6: ...high speed connections to a server or network backbone For example you can Connect switches to each other with high speed links Link to high speed servers Provide 10 100 1000 copper and fiber connectivity Your NETGEAR ProSafe FS726TP Smart Switch with PoE also provides the benefit of administrative management with a complete package of features for the observation configuration and control of your...

Page 7: ...o Discovery application program for discovering and managing the switches on the network Support flash upgrading configuration backup restore and factory reset Full compatibility with IEEE standards IEEE 802 3i 10BASE T IEEE 802 3u 100BASE TX IEEE 802 3z ab 1000BASE X 1000Base T IEEE 802 3af Power over Ethernet IEEE 802 3x full duplex flow control Auto sensing and auto negotiating capabilities for...

Page 8: ...ains the following NETGEAR ProSafe FS726TP Smart Switch with PoE Rubber footpads for tabletop installation Power cord Rack mount kit for installing the switch in a 19 inch rack Installation guide Smart Switch Resource CD with Smart Wizard Discovery and User s manual Warranty Support Information Card If any item is missing or damaged contact your place of purchase immediately ...

Page 9: ...f the attached device All ports support only unshielded twisted pair UTP cable terminated with an 8 pin RJ 45 plug To simplify the procedure for attaching devices all RJ 45 ports support Auto Uplink This technology lets you attach devices to the RJ 45 ports either straight through or crossover cables When you insert a cable into the switch s RJ 45 port the switch automatically Senses whether the c...

Page 10: ...other device 10 100M Ports Link ACT 100M z Solid Green A valid 10 100Mbps link is established on the port z Blinking Green Packets transmission or reception is occurring on the port at 100Mbps z OFF No 10 100Mbps link is established on the port z Solid Green A valid 100Mbps link is established on the port z OFF No 10Mbps link is established on the port PoE Ports ports 1 to 12 POE POE fault z Solid...

Page 11: ... insert a small device such as a paper clip into the opening to press the recessed button The LEDs on the switch should go out and then come back on as the switch goes through its Power On Switch Test POST Factory Defaults Button The FS726TP has a Factory Default Button to enable you to clear out the current configuration and return to the factory settings This will clear out all settings includin...

Page 12: ...air exhausts hot air vents and heaters Operating humidity The installation location should have a maximum relative humidity of 90 non condensing Ventilation Do not restrict airflow by covering or obstructing air inlets on the sides of the switch Keep at least 2 inches 5 08 centimeters free on all sides for cooling Be sure there is adequate airflow in the room or wiring closet where you intend to i...

Page 13: ... crossover cables Figure 4 2 Connecting Devices to the Switch Connect each device to an RJ 45 network port on the switch s front panel see Figure 4 4 Use Category 5 Cat5 unshielded twisted pair UTP cable terminated with an RJ 45 connector to make these connections Note Ethernet specifications limit the cable length between the switch and the attached device to 100 m 328 ft Step 5 Installing an SFP...

Page 14: ...Power LED does not go on check that the power cable is plugged in correctly and that the power source is good If this does not resolve the problem refer to Appendix B Troubleshooting Step 7 Switch Management through a Web Browser or the PC Utility for Initial Configuration Your NETGEAR ProSafe FS726TP Smart Switch with PoE contains software for viewing changing and monitoring the way it works This...

Page 15: ... connections such as those associated with switch ports that are experiencing congestion or failure or exceeding an administrator defined threshold Forwarding The process of sending a packet toward its destination using a networking device Filtering The process of screening a packet for certain characteristics such as source address destination address or protocol Filtering is used to determine wh...

Page 16: ... paths ensuring that only one route exists between any two LANs Spanning Tree Protocol STP A protocol that finds the most efficient path between segments of a multi looped bridged network STP allows redundant switches and bridges to be used for network resilience without the broadcast storms associated with looping If a switch or bridge falls a new path to a redundant switch or bridge is opened Sw...

Page 17: ...ected ACT LED is flashing continuously on all connected ports and the network is disabled A network loop redundant path has been created see Figure 2 3 Break the loop by ensuring that there is only one path from any networked device to any other networked device Additional Troubleshooting Suggestions If the suggestions in Table B 1 do not resolve your problem refer to the troubleshooting suggestio...

Page 18: ...e Specifications Forwarding modes Store and forward Bandwidth 8 8 Gbps Network latency Less than 20 microseconds for 64 byte frames in store and forward mode for 100 Mbps to 100 Mbps transmission Buffer memory 256 KB embedded memory per unit Address database size 8 000 media access control MAC addresses per system Mean Time Between Failure MTBF 300 000 hours 34 years Power Supply 5VDC 6A 48VDC 100...

Page 19: ...Page19of19 Modules AGM731F 1000BASE SX SFP GBIC for multimode fiber AGM732F 1000BASE LX SFP GBIC for single mode fiber AGM733 1000Base ZX SFP GBIC for long distance single mode fiber ...

Reviews: