SB72 User's Manual, 350030-006
Page 8
Device Connection Settings
Server Listen Port:
Select the checkbox and enter the listening port number you want the TCP
serial server to listen on for incoming connections.
Client Activity Timeout
and Disconnect
If no activity is detected on a TCP/IP connection within this timeout period,
the TCP server will drop the connection.
Client Override Timeout
If no activity is detected on a TCP/IP connection within this timeout period,
the TCP server will disconnect the current TCP/IP connection and allow the
new incoming connection request to connect.
Outgoing Connections
If this option is enabled, the SB72 will initiate a connection to an outside
destination when the selected conditions are met.
Options are:
•
Don't Initiate Connections
•
Connect on Power-up
•
Connect when receiving serial data
If this option is enabled, you must enter values for the outgoing destination
port number and destination address.
Outgoing Port Number
Destination port number
Outgoing Address
Either the name (e.g. www.netburner.com) or numeric IP address (e.g.
10.1.1.2) of the destination
Outgoing Timeout
Inactivity timeout for the outgoing connection