NetApp FAS25 Series Manual Download Page 8

You can safely respond 

y

 to these prompts.

2.  On the node with the replaced component, enter the following command at the LOADER prompt:

boot_diags

Note: 

You must enter this command from the LOADER prompt for system-level diagnostics to function properly. The

boot_diags

 command starts special drivers designed specifically for system-level diagnostics.

Important: 

During the 

boot_diags

 process, you might see the following prompts:

A prompt warning that when entering Maintenance mode in an HA configuration you must ensure that the partner
remains down.

You can safely respond 

y

 to these prompts.

The Maintenance mode prompt (*>) appears.

3.  Clear the status logs by entering the following command:

sldiag device clearstatus

4.  Verify that the log is cleared by entering the following command:

sldiag device status

The following default response is displayed:

SLDIAG: No log messages are present.

5.  Run the sensor-related environmental tests for the RTC battery by entering the following command from the Maintenance

mode prompt:

sldiag device run -dev env

Note: 

See the 

System-Level Diagnostics Guide for a description of the types of tests you can run.

6.  View the status of the test by entering the following command:

sldiag device status

Your storage system provides the following output while the tests are still running:

There are still test(s) being processed.

After all the tests are complete, the following response appears by default:

*> <SLDIAG:_ALL_TESTS_COMPLETED>

7.  Verify that no hardware problems resulted from the addition or replacement of hardware components on your system by

entering the following command:

sldiag device status [-dev devtype] [-name device] -long -state failed

System-level diagnostics returns you to the prompt if there are no test failures, or lists the full status of failures resulting
from testing the component.

8.  Proceed based on the result of the preceding step:

8

Replacing an RTC battery

Summary of Contents for FAS25 Series

Page 1: ...the target controller using different procedures depending on whether it is part of an HA pair or a stand alone system Shutting down a controller module in an HA pair To shut down a controller module...

Page 2: ...e cf status or storage failover show command If Then Neither node is in takeover mode Go to the next step in this procedure The healthy node took over the impaired node The impaired node is in a state...

Page 3: ...m is configured in Then issue this command 7 Mode halt Clustered Data ONTAP halt local After you issue the command and respond Y to halt the node wait until the system stops at the LOADER prompt Atten...

Page 4: ...ement arms on a FAS2552 system The procedure is the same for all FAS2500 systems 4 Squeeze the latch on the cam handle until it releases as shown in the following illustration Open the cam handle full...

Page 5: ...ule cover Removing an RTC battery You must follow a specific sequence of steps to remove the RTC battery from the controller module Steps 1 Locate the RTC battery at the right rear of the controller m...

Page 6: ...and that the polarity is correct Reinstalling the controller module and booting the system After you replace a component within the controller module you must reinstall the controller module in the sy...

Page 7: ...Attention Do not use excessive force when sliding the controller module into the chassis you might damage the connectors b Reconnect the power cables to the power supplies and to the power sources tur...

Page 8: ...IAG No log messages are present 5 Run the sensor related environmental tests for the RTC battery by entering the following command from the Maintenance mode prompt sldiag device run dev env Note See t...

Page 9: ...modules in the chassis leave the power supplies turned on to provide power to the other controller module If you have one controller module in the chassis turn off the power supplies and unplug them...

Page 10: ...current year mm is the current month If the month is omitted the default is the current month dd is the current day If the day is omitted the default is the current day hh is the current hour using a...

Page 11: ...E LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS...

Page 12: ...shtml Apple is a registered trademark and QuickTime is a trademark of Apple Inc in the United States and or other countries Microsoft is a registered trademark and Windows Media is a trademark of Micr...

Reviews: