NetApp FAS25 Series Manual Download Page 2

node1 true     true
node2 true     true
node3 true     true
node4 true     true
4 entries were displayed.

b.  Take one of the following actions, depending on the result of the command:

If...

Then...

All nodes show 

true

 for both health and eligibility.

Proceed to Step 3.

The impaired node shows 

false

 for health.

Proceed to the next step.

Any nodes show 

false

 for eligibility.

Resolve any cluster issues as needed before continuing with this
procedure.

Any nodes other than the impaired node show 

false

 for health. Correct the problems that cause the health issues on the nodes before

continuing with this procedure.

2.  Check the status of the impaired node (the node you want to perform maintenance on) by entering the following command at

the system console of either node:

For...

Issue the command...

7-Mode

cf status

Clustered Data ONTAP

storage failover show

3.  Take one of the following actions, depending on the result of the 

cf status

 or 

storage failover show

 command:

If...

Then...

Neither node is in takeover mode

Go to the next step in this procedure.

The healthy node took over the
impaired node

The impaired node is in a state where you can begin removing it from the system chassis.

The impaired node took over the
healthy node

a.  Correct the problem that caused the takeover.

b.  Enter the 

cf giveback

 command (7-Mode) or 

storage failover giveback

impaired_node_name

 command (clustered Data ONTAP) from the impaired node

console.

c.  Go back to the Step 1.

4.  Take over and power down the impaired node by taking the following steps:

a.  Enter one of the following commands from the healthy node’s console and wait for the takeover to complete:

For systems operating in...

Issue the command...

7-Mode

cf takeover

Clustered Data ONTAP

In Data ONTAP 8.1.0 or earlier:

storage failover takeover -fromnode

healthy_node_name

In Data ONTAP 8.2 or later:

storage failover takeover -ofnode

impaired_node_name

The impaired node is taken over and then automatically reboots and displays the 

Waiting for giveback...

message.

2

Replacing an RTC battery

Summary of Contents for FAS25 Series

Page 1: ...the target controller using different procedures depending on whether it is part of an HA pair or a stand alone system Shutting down a controller module in an HA pair To shut down a controller module...

Page 2: ...e cf status or storage failover show command If Then Neither node is in takeover mode Go to the next step in this procedure The healthy node took over the impaired node The impaired node is in a state...

Page 3: ...m is configured in Then issue this command 7 Mode halt Clustered Data ONTAP halt local After you issue the command and respond Y to halt the node wait until the system stops at the LOADER prompt Atten...

Page 4: ...ement arms on a FAS2552 system The procedure is the same for all FAS2500 systems 4 Squeeze the latch on the cam handle until it releases as shown in the following illustration Open the cam handle full...

Page 5: ...ule cover Removing an RTC battery You must follow a specific sequence of steps to remove the RTC battery from the controller module Steps 1 Locate the RTC battery at the right rear of the controller m...

Page 6: ...and that the polarity is correct Reinstalling the controller module and booting the system After you replace a component within the controller module you must reinstall the controller module in the sy...

Page 7: ...Attention Do not use excessive force when sliding the controller module into the chassis you might damage the connectors b Reconnect the power cables to the power supplies and to the power sources tur...

Page 8: ...IAG No log messages are present 5 Run the sensor related environmental tests for the RTC battery by entering the following command from the Maintenance mode prompt sldiag device run dev env Note See t...

Page 9: ...modules in the chassis leave the power supplies turned on to provide power to the other controller module If you have one controller module in the chassis turn off the power supplies and unplug them...

Page 10: ...current year mm is the current month If the month is omitted the default is the current month dd is the current day If the day is omitted the default is the current day hh is the current hour using a...

Page 11: ...E LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS...

Page 12: ...shtml Apple is a registered trademark and QuickTime is a trademark of Apple Inc in the United States and or other countries Microsoft is a registered trademark and Windows Media is a trademark of Micr...

Reviews: