NetApp FAS22 Series Manual Download Page 8

If the system-
level diagnostics
tests...

Then...

Were completed
without any
failures

a. Clear the status logs by entering the following command:

sldiag device clearstatus

b. Verify that the log is cleared by entering the following command:

sldiag device status

The following default response is displayed:

SLDIAG: No log messages are present.

c. Exit Maintenance mode by entering the following command:

halt

d. Enter the following command at the firmware prompt to reboot the storage system:

boot_ontap

e. If your system is in an HA pair, enter the 

cf giveback

 command (7-Mode) or 

storage failover

giveback

 command (Cluster-Mode) from the partner node console.

You have completed system-level diagnostics.

Resulted in some
test failures

Determine the cause of the problem:

a. Exit Maintenance mode by entering the following command:

halt

After you issue the command, wait until the system stops at the LOADER prompt.

b. Turn off or leave on the power supplies, depending on how many controller modules are in the target chassis:

If you have two controller modules in the chassis, leave the power supplies turned on to provide power to
the partner node.

If you have one controller module in the chassis, turn off the power supplies and unplug them from the
power sources.

c. Check the controller module and verify that you have observed all the considerations identified for running

system-level diagnostics, that cables are securely connected, and that hardware components are properly
installed in the storage system.

d. Boot the target node, interrupting the boot by pressing Ctrl-c:

If you have two controller modules in the chassis, fully seat the controller module in the chassis.

The controller module boots up when fully seated.

If you have one controller module in the chassis, connect the power supplies and turn them on.

e. Rerun the system-level diagnostic tests.

9. Repeat the preceding steps for the other controller module, if necessary.

Related information

System-Level Diagnostics Guide

8

Replacing the chassis on a FAS22xx system

Summary of Contents for FAS22 Series

Page 1: ...g data This procedure is written with the assumption that you are moving the controller module or modules to the new chassis and that the chassis is a new component from NetApp Steps 1 Removing the po...

Page 2: ...of steps Steps 1 If you are not already grounded properly ground yourself 2 Unplug the system cables and SFPs from the controller module as needed and keep track of where the cables were connected Lea...

Page 3: ...ve the bezel from the front of the system 2 Remove the disk drives For the Then FAS2220 and FAS2240 4 systems a Press in the release button on the far left of the carrier face front 3 0TB 3 0TB 3 0TB...

Page 4: ...assis and lock the cam handle by pushing it up and against the disk drive holder Be sure to close the cam handle slowly so that it aligns correctly with the front of the drive carrier You will hear it...

Page 5: ...em cabinet or angel wings in an equipment rack 3 Slide the chassis all the way into the equipment rack or system cabinet 4 Secure the rear of the chassis to the support rail if applicable using the sc...

Page 6: ...pplies to different power sources and then turn them on 6 Press Ctrl c to stop the boot process and display the boot menu when prompted to do so and then select the option to boot to Maintenance mode...

Page 7: ...nd sldiag device status The following default response is displayed SLDIAG No log messages are present 5 Run the environmental diagnostics test by entering the following command from the Maintenance m...

Page 8: ...f or leave on the power supplies depending on how many controller modules are in the target chassis If you have two controller modules in the chassis leave the power supplies turned on to provide powe...

Page 9: ...Management LockVault Manage ONTAP MetroCluster MultiStore NearStore NetCache NOW NetApp on the Web Onaro OnCommand ONTAPI OpenKey PerformanceStak RAID DP ReplicatorX SANscreen SANshare SANtricity Secu...

Reviews: