If the system-
level diagnostics
tests...
Then...
Were completed
without any
failures
a. Clear the status logs by entering the following command:
sldiag device clearstatus
b. Verify that the log is cleared by entering the following command:
sldiag device status
The following default response is displayed:
SLDIAG: No log messages are present.
c. Exit Maintenance mode by entering the following command:
halt
d. Enter the following command at the firmware prompt to reboot the storage system:
boot_ontap
e. If your system is in an HA pair, enter the
cf giveback
command (7-Mode) or
storage failover
giveback
command (Cluster-Mode) from the partner node console.
You have completed system-level diagnostics.
Resulted in some
test failures
Determine the cause of the problem:
a. Exit Maintenance mode by entering the following command:
halt
After you issue the command, wait until the system stops at the LOADER prompt.
b. Turn off or leave on the power supplies, depending on how many controller modules are in the target chassis:
•
If you have two controller modules in the chassis, leave the power supplies turned on to provide power to
the partner node.
•
If you have one controller module in the chassis, turn off the power supplies and unplug them from the
power sources.
c. Check the controller module and verify that you have observed all the considerations identified for running
system-level diagnostics, that cables are securely connected, and that hardware components are properly
installed in the storage system.
d. Boot the target node, interrupting the boot by pressing Ctrl-c:
•
If you have two controller modules in the chassis, fully seat the controller module in the chassis.
The controller module boots up when fully seated.
•
If you have one controller module in the chassis, connect the power supplies and turn them on.
e. Rerun the system-level diagnostic tests.
9. Repeat the preceding steps for the other controller module, if necessary.
Related information
System-Level Diagnostics Guide
8
Replacing the chassis on a FAS22xx system