authentication keys.
If the command fails, contact Customer Support.
◦
If the
Key Manager type
=
onboard
and the
Restored
column = anything other than
yes/true
,
use the
security key-manager onboard sync
command to re-sync the Key Manager type.
Use the
security key-manager key query
command to verify that the
Restored
column =
yes/true
for all authentication keys.
11. Connect the console cable to the partner node.
12. Give back the node using the
storage failover giveback -fromnode local
command.
13. Restore automatic giveback if you disabled it by using the
storage failover modify -node local
-auto-giveback true
command.
Return the failed part to NetApp - AFF A250
After you replace the part, you can return the failed part to NetApp, as described in the
RMA instructions shipped with the kit. Contact technical support at
, 888-
463-8277 (North America), 00-800-44-638277 (Europe), or +800-800-80-800
(Asia/Pacific) if you need the RMA number or additional help with the replacement
procedure.
Chassis
Replace the chassis - AFF A250
To replace the chassis, you must move the bezel, controller modules, and NVMe drives
from the impaired chassis to the replacement chassis, and then remove the impaired
chassis from the equipment rack or system cabinet and install the replacement chassis in
its place.
About this task
• All other components in the system must be functioning properly; if not, you must contact technical support.
• You can use this procedure with all versions of ONTAP supported by your system.
• This procedure is written with the assumption that you are moving the bezel, NVMe drives, and controller
modules to the new chassis, and that the replacement chassis is a new component from NetApp.
• This procedure is disruptive. For a two-node cluster, you will have a complete service outage and a partial
outage in a multi-node cluster.
Shut down the controllers - AFF A250
You must shut down the node or nodes in the chassis prior to moving them to the new
chassis.
About this task
• If you have a cluster with more than two nodes, it must be in quorum. If the cluster is not in quorum or a
healthy node shows
false
for eligibility and health, you must correct the issue before shutting down the
30