NETBEAT
USER MANUAL
35
MAINTENANCE
User responsibility
The following requisites are to be assured by the user:
Conducting monthly inspection and ensuing Preventive Maintenance procedures.
Appropriate mains electricity supply.
Cellular connectivity (if required).
WiFi connectivity of suitable capacity.
Preventive Maintenance - monthly inspection
Visually inspect the NetMCU and the NetRTUs exterior for:
Appropriate environmental conditions (see Environmental conditions,
Physical integrity.
Antennas integrity and connection.
Open the units
ATTENTION
Do not attempt to open the NetMCU or the NetRTU by hand or with inappropriate tools.
Open the NetMCU with a flatbed screwdriver - Minimum 10mm (3/8"), or a coin.
Open the NetMCU with a 8mm (¼") flatbed screwdriver.
Visually inspect the NetMCU and the NetRTUs interior for:
Condensation
Light to medium condensation can be addressed using silica gel packets (consult the manufacturer).
Heavy condensation - contact your Netafim™ local representative for support.
Insect penetration and settlement
Can be addressed using insecticides (spray or pellets, depending on the type of insect).
WARNING
Do not spray directly onto electrical components and circuit boards.
Exposed wires (First time inspection only)
RTU Battery Replacement
CAUTION
Before Proceeding, see Safety - Batteries,
Open the NetRTU with a 8mm (¼") flatbed screwdriver.
ATTENTION
Do not attempt to open the NetRTU by hand or with inappropriate tools.
Insert 3 AA size batteries, type –
L91 Lithium batteries by Energizer. Observe polarity.
The NetRTU should turn on automatically.
Make sure the cover gasket is in place.
Close the NetRTU