NETBEAT
USER MANUAL
11
SYSTEM DESCRIPTION
Easy expansion
Based on internal, easy to install, I/O tiles. Integrates 2 types of I/O tiles (optional 6 tiles per NetMCU)
Power supply
Mains power
(100 to 250 VAC 50/60Hz)
10-15 VDC (Battery & Solar panel)
Touch screen
Optional
Specifications
Operation
temperature
With touch screen:
-20ºC - 55ºC / -4ºF - 131ºF
Without touch screen:
-20ºC - 65ºC / -4ºF - 149ºF
Dimensions
635 x 573 x 252 mm
(25 x 22
9
⁄
16
x 10”)
MCU – Power Tile
The Power tile receives 12VDC input voltage from the Power Supply.
It supplies the voltage to all tiles and charges the backup battery with
12VDC output voltage.
MCU max power is 100W at 45°C (113°F)
MCU power supply
Parameter
Rating
Input
Voltage range
90 ~ 132VAC / 180 ~ 264VAC,
by switch
Frequency range 47 ~ 63Hz
AC current
4A/115VAC 2.2A/230VAC
Output
DC voltage
12V
Current range
0 ~ 17A
Rated power
204W
MCU backup battery
Parameter
Rating
Nominal voltage 12V
Nominal capacity 5Ah (20hr)
Reset
Status
LEDs
Power
supply in
Battery in