10
S25##3710A
RESTRICTION PLATE
A set of restriction plates is supplied with your stove to reduce flue draft when required.
These reduction plates are to be used in the following vent configurations:
Top flue exit
2' vertical rise, 2' horizontal length
6' vertical rise, 24' horizontal length
Natural Gas
70mm (2¾") restriction plate
58mm (2¼") restriction plate
Propane
No restriction plate required
80mm (3
⅛
") restriction plate
Rear flue exit
2' horizontal length (w / snorkel)
Natural Gas
60mm (2
⅜
") restriction plate
Propane
70mm (2¾") restriction plate
Install the restrictor plate directly at the stove outlet as follows:
1. Unscrew and remove the cast iron flue collar.
2. Unscrew and remove the inner flue outlet as well as the gasket.
3. Place the restriction plate on the stove's inner firebox so that it reduces the exhaust outlet diameter.
4. Replace gasket and inner flue collar and fasten using the four screws.
5. Finally, replace the cast iron flue collar.
58mm (2¼") restriction plate
restriction plate
gasket
inner flue outlet
cast iron flue collar
70mm (2¾") restriction plate
60mm (2
⅜
") restriction plate
80mm (3
⅛
") restriction plate