Specifications 

Features

 

Description

 

Appearance

 

Metal case, anti-explosion and anti-tamper

 

Waterproof

 

IP65

 

Input voltage

 

DC: 12-24V AC: 12-18V

 

Users(max)

 

2500

 

PIN

 

4 digits

 

Master Card

 

Add/Delete User

 

Proximity Reader (RFID)

 

Supports  Wiegand  26bits,  PIN/Wiegand  output  is  a  virtual  number,  Site 
Code / Reader Address is set within the S2 Controller

 

Connect External reader

 

Can Connect any External EM/HID/IC readers with Wiegand 26 bit Output

 

Connect High Power Alarm

 

External Current of the Alarm <=3A

 

Dimensions 

135mm x 57mm x 25mm 

Operating Voltage 

DC:12~24V  AC: 12~18V 

Current 

Idle – 35mA / Active <80mA 

 

Card Reading Distance 

3~6 cm 

Operating Temperature 

-40~60 Deg C 

Lock Output Load 

2A Max 

 

 

 

 

Head Office: 

4/167 Prospect Hwy, 

Seven Hills NSW, Australia 

Phone +61 2 8825 9222 

email : [email protected] 

Sydney Office - (02) 8825 9222 

Melbourne Office -(03) 9875 6400 

Brisbane Office - (07) 3399 4910 

Perth Office -(08) 9328 2511 

Adelaide Office - (08) 8152 0000

 

Email 

[email protected] 

Summary of Contents for S2

Page 1: ...1 S2 Metal Waterproof Access Control Unit Installation and User Manual Ness Part No 101 082 ...

Page 2: ...er is granted access or can interface to 3rd party products via its 26 Bit Wiegand output Installation Drill a hole in the wall to match the location of the cable at the rear of the S2 or mount a suitable wall mount junction box Thread the cable through cable hole and connect related cables Take care to insulate the unused cables to prevent shorting Fix the back cover to the wall or distribution b...

Page 3: ...one second and then glow steady Red while S2 awaits Program Option Commands To Exit Program Mode press If no keys are pressed for 60 seconds S2 will automatically exit Program Mode and resume Operation Mode The following options can be accessed and programmed in Program Mode 2 Changing the Master Code Master Code must be 6 digits long Can only be done in Master Programming Mode Press 0 The LED wil...

Page 4: ...n Press to end If more Users are to be added repeat the process for each User Press 1 Enter ID No 1 Enter PIN 1 Enter ID No 2 Enter PIN 2 All PIN numbers must be 4 Digits of any number combination however they must not be 1234 3 4 Adding Card Users Sequentially Multiple Users can be added sequentially as either a Card or Pin Press 1 Present Card 1 to the Reader Enter ID No 1 Present Card 2 to the ...

Page 5: ... to be deleted Enter ID Number of the next User to be deleted 4 3 Deleting ALL users Press 2 The LED will glow Orange Press 0000 followed by the button The LED will then flash Green confirming that all Users have been deleted Press 2 0000 4 4 Deleting Users using the Delete User Master Card Cards may be deleted anytime without entering Programming mode using the Delete User Master Card that comes ...

Page 6: ...nput When enabled If the door is opened normally but not closed within 1 minute the buzzer will sound for 1 minute If the door is forced open opened by an unauthorized user the buzzer and alarm output will be activated 9 Security Mode Settings for Invalid Access Attempts Can only be done in Master Programming Mode Three options are provided for programming Keypad Lockout Alarm Output in the event ...

Page 7: ...uired Site Code 0 255 Site Code must be between 0 and 255 11 Setting the Address of the Reader Default 0 Can only be done in Master Programming Mode When using S2 with security equipment that supports addressable readers such as Ness D8XD 16XD Panels Ness 6DA controllers etc it may be necessary to set the address of the reader When programmed to Address 0 Default the Wiegand Output uses standard 2...

Page 8: ... Number the PIN will be assigned to Enter Old PIN Enter New PIN Repeat the NEW PIN OPERATION Unlocking the Door By Card OR PIN If the Door Access Control Setting Section 6 is programmed to Card or PIN access will be granted by presenting a valid Card to the Reader or by entering a valid PIN Either OR If successful the LED will flash Green and the Relay will activate for the Unlock time If unsucces...

Page 9: ...lay will activate for the unlock period If no PIN is entered within 5 seconds S2 will time out and the LED will return to its normal red Flashing mode AND S2 will sound 3 beeps if the entered PIN is invalid or incorrect Resetting Restoring an Alarm If an Alarm occurs for any reason e g Door Forced Open or Open Too Long it can be reset by presenting A valid card to the Reader or by entering the Mas...

Page 10: ...any External EM HID IC readers with Wiegand 26 bit Output Connect High Power Alarm External Current of the Alarm 3A Dimensions 135mm x 57mm x 25mm Operating Voltage DC 12 24V AC 12 18V Current Idle 35mA Active 80mA Card Reading Distance 3 6 cm Operating Temperature 40 60 Deg C Lock Output Load 2A Max Head Office 4 167 Prospect Hwy Seven Hills NSW Australia Phone 61 2 8825 9222 email ness ness com ...

Reviews: