specIfIcatIons

OpERaTiNG VOLTaGE

9V Lithium battery

QUiESCENT CURRENT DRaW

<10µa

SiGNaLS TRaNSMiTTED

1. alarm/restore from reed switch or external input.

 

2. Tamper.

 

3. Low battery signal (~6V).

 

4. Learn message (on power up).

RaDiO SECURiTy
(When used with a compatible Ness Receiver)

1. Encrypted signals. 

 

2. Supervised operation.

iNpUT SELECTiON LiNk

internal reed or external input or both in series.

ExTERNaL iNpUT

accepts N.C. devices. 

 

400mm maximum cable length to input.

TaMpER SWiTCh

Cover tamper switch.

REED SWiTCh

Miniature glass envelope, matching magnet supplied.

ViBRaTiON aDJUSTMENT

Rotary min/max sensitivity adjustment.

RaDiO FREQUENCy

303.85Mhz

TRaNSMiT pOWER

100µW

COMpaTiBiLiTy

all Ness radio receivers.

DiMENSiONS

78(h) x 73(w) x 27(d) mm

Ness 

RR2 UNiVERSaL TRaNSMiTTER

installation Notes 
Revision 2.1 Jan 2015

Document part number 890-324
For the product 100-527 RR2 Universal 
Transmitter 304Mhz

© Ness Corporation pty Ltd aBN 28 069 984 372
Specifications may change without notice.

www.nesscorporation.com

National Customer Service Centre
ph: 1300 551 991
[email protected]

Summary of Contents for RR2

Page 1: ...es vibration sensors push buttons or any N C device On board adjustable vibration analyser for Nessensor vibration sensors On board reed switch 9V battery operation Fully supervised encrypted signals Compatible with all Ness radio receivers Ultra low standby current draw With on board vibration analyser Ness Universal Transmitter ...

Page 2: ...arden shed Roller Reed Switch protecting Garage roller tilt door Warehouse door Caravan or boat parked at home Nessensor protecting Door and window frames Cars in car yards Display cases in shops Jewellery cabinets Safes strongroom doors Links EBI Link Selects the active input EB position Only the external input is active BI position Only the on board reed switch is active Open position link parke...

Page 3: ...sensor can be adjusted by rotating the sensor s body to provide low medium and high sensitivity Multiple Nessensors can be connected in series although this is limited by the maximum cable length of 400mm allowed on the External Input Reed Switch The on board reed switch can be used to protect openings using the magnet supplied Mount the magnet on the moveable door or window and the Ness Universal...

Page 4: ...ble length to input Tamper switch Cover tamper switch Reed switch Miniature glass envelope matching magnet supplied Vibration adjustment Rotary min max sensitivity adjustment Radio frequency 303 85MHz Transmit power 100µW Compatibility All Ness radio receivers Dimensions 78 h x 73 w x 27 d mm Ness RR2 Universal Transmitter Installation Notes Revision 2 1 Jan 2015 Document part number 890 324 For t...

Reviews: