background image

3

Learn message

The Ness Universal Transmitter sends its Learn 
Message  when  the  battery  is  first  connected. 
This  is  used  to  teach  the  transmitter’s  unique 
code  to  the  Ness  control  panel/receiver  being 
programmed.  Refer  to  the  control  panel’s 
programming instructions.

VIBratIon anaLyser

The on-board vibration analyser operates on the 
External input and provides adjustable sensitivity 
for Nessensor™ vibration sensors.

Sensitivity is adjusted using the onboard rotary 
trimpot.  Turn  fully  anti-clockwise  for  lowest 
sensitivity, fully clockwise for highest sensitivity. 
The middle position is likely to be suitable for most 
situations. 

use the highest sensitivity setting 

with caution.

in addition to the analyser’s sensitivity adjustment, 
the overall sensitivity of the Nessensor™ can be 
adjusted by rotating the sensor’s body to provide 
low, medium and high sensitivity.

Multiple Nessensors™ can be connected in series, 
although  this  is  limited  by  the  maximum  cable 
length of 400mm allowed on the External input.

reed swItch

The on-board reed switch can be used to protect 
openings using the magnet supplied.

Mount  the  magnet  on  the  moveable  door  or 
window  and  the  Ness  Universal  Transmitter  on 
the fixed frame. align the magnet with the reed 
switch leaving a gap of no more than 15mm when 
the door/window is closed.

The magnet is not required if the reed switch is 
not being used.

ON-BOARD REED SWITCH

THE EXTERNAL INPUT

IS ACTIVE

THE ONBOARD REED

SWITCH IS ACTIVE

THE

ONBOARD REED SWITCH ARE ACTIVE

EXTERNAL INPUT AND THE

(Link is shown parked)

INPUT SELECTION LINKS

LED

TAMPER

MIN

MAX

TRIMPOT

EXTERNAL INPUT

MAGNET

LINKS

RED

BLUE

N.C. contacts

N.C. contacts

NESSENSOR™

REED SWITCH

PUSH BUTTON

* Multiple devices must be wired in series.

<15m

m

73mm

78mm

Summary of Contents for RR2

Page 1: ...es vibration sensors push buttons or any N C device On board adjustable vibration analyser for Nessensor vibration sensors On board reed switch 9V battery operation Fully supervised encrypted signals Compatible with all Ness radio receivers Ultra low standby current draw With on board vibration analyser Ness Universal Transmitter ...

Page 2: ...arden shed Roller Reed Switch protecting Garage roller tilt door Warehouse door Caravan or boat parked at home Nessensor protecting Door and window frames Cars in car yards Display cases in shops Jewellery cabinets Safes strongroom doors Links EBI Link Selects the active input EB position Only the external input is active BI position Only the on board reed switch is active Open position link parke...

Page 3: ...sensor can be adjusted by rotating the sensor s body to provide low medium and high sensitivity Multiple Nessensors can be connected in series although this is limited by the maximum cable length of 400mm allowed on the External Input Reed Switch The on board reed switch can be used to protect openings using the magnet supplied Mount the magnet on the moveable door or window and the Ness Universal...

Page 4: ...ble length to input Tamper switch Cover tamper switch Reed switch Miniature glass envelope matching magnet supplied Vibration adjustment Rotary min max sensitivity adjustment Radio frequency 303 85MHz Transmit power 100µW Compatibility All Ness radio receivers Dimensions 78 h x 73 w x 27 d mm Ness RR2 Universal Transmitter Installation Notes Revision 2 1 Jan 2015 Document part number 890 324 For t...