![Ness Radio Siren Installation Notes Download Page 6](http://html.mh-extra.com/html/ness/radio-siren/radio-siren_installation-notes_1669376006.webp)
rAdio sirEn trAnsmittEr
the Ness radio siren transmitter (rst) is
purpose designed to send a variety of alarm
signals to the rsI and rss radio sirens.
the rst is a miniature transmitter board with
flying leads fitted allowing it to be easily connected
to a control panel.
INPuts
12V +/- wires: Constant 12VDC input.
Input 1 - White: sends oN signal or aux signal
depending on the setting of LINK 1.
Input 2 - Blue: sends PaNIC signal or oN signal
depending on the setting of LINK 1.
LearN MessaGe
the rst sends a learn message when power
is applied.
LeD INDICator
singlE FlAsh
Alarm Transmitted
ThREE FlAshEs
learn signal sent
ConTinUoUs FlAsh
Error Condition
ProGraMMING LINKs
the rst has two programming links.
link 1
determines the type of signal sent by
inputs 1 and 2.
LINK 1
Alarm Type setting
linK 1 PosiTion
oFF
(dEFAUlT)
on
action
type oF meSSage Sent
AlARM inPUT 1 (white)
strobe
siren
AlARM inPUT 2 (Blue)
siren
Fire
REsToRE inPUT 1
off
off
REsToRE inPUT 2
off
off
link 2
sets both inputs for positive or negative
trigger.
Link oFF: Negative trigger (Factory Default).
each input can be held high or floating. Pull
low to trigger.
Link oN: Positive trigger. each input must
be held low by an external 2k2 resistor. Pull
high to trigger.
R8
eco8x
d24
d8x / d16x
0v
C
0v
siREn+
+12v
+12v
PiEZ –
REsET –
REsET –
*
sTR –
sTR –
* sTRoBE wire is not used on the R8 panel.
The Rss strobe output will still turn on but it
will reset after 5 minutes along with the siren
output.
rst CoNNeCtIoN exaMPLe For Most Ness CoNtroL PaNeLs
Link 1 is off for negative trigger
A 2K2 resistor is required 12v and REsET- if a 12v Piezo siren is
also connected to the REsET output. The resistor can be omitted if the RsT
is the only device on the REsET output.