DETECTING INTRUDERS
Monitor Mode
Use Monitor Mode to guard an unattended part of the property while
occupying the rest. Your system may be programmed so that have the
choice of arming two different monitor areas (dual monitor mode),
otherwise there is only one monitor area (single monitor mode).
Single Monitor Mode:
Ensure all zones in the monitor area are sealed and then partially arm the
Panel as follows:
(one button)
MONITOR
(two button)
MONITOR ENTER
(code)
MONITOR code ENTER
Dual Monitor Mode:
Ensure all zones in the monitor area are sealed and then partially arm the
Panel as follows:
(one button)
MONITOR 2
MONITOR 1 -or-
(two button)
MONITOR 1 ENTER -or-
-or-
MONITOR 2 ENTER
There is now a fixed time for anyone in the monitor area to leave. This is
the same exit delay as occurs upon full arming.
If, when you attempt to arm, you get a long bee-eep, then check this list
of things that prevent arming:
- Siren sounding when MONITOR hit
- Attempt to arm one button or two button when code mandatory
- Code keyed incorrectly
- Already armed
- In program or exclude mode
A zone that alarms while the Panel is in monitor mode may sound the
keypad(s) with a beep every half second. This will continue for a time
equal to the entry delay. If the alarm is not reset within this time, then the
siren will sound for a 2 second burst. (These details depend on how your
PRO-LX User Manual
15
MONITOR (slow)
AREA1 (slow)
AREA2 (slow)
Provided
for
Download
by
www.bendigosecurity.com.au