Ness M1KAM Quick Start Manual Download Page 3

Page 3

Summary of Contents for M1KAM

Page 1: ...nects to the 4 wire keypad data bus in place of a traditional M1 Keypad Since the maximum number of keypads on an M1 or M1EZ8 is 16 the maximum number of M1KAM modules and controlled doors is 16 minus any installed keypads Even though an M1 Keypad can accept a 26 bit access reader the M1KAM is a more powerful and less expensive access solution For example the M1KAM includes a relay door unlock out...

Page 2: ...Identification of the Relay Output on the M1KAM is based on the Data Bus Address of the M1KAM See Table 1 under Setting the Data Bus Address for more details 5 Install a proximity reader 26 BIT Wiegand compatible reader and connect it to the M1KAM as follows 26 Bit Wiegand Reader Requires a 4 wire connection 2 for power and 2 for data to the M1KAM Ideally the reader should be powered from the loca...

Page 3: ...Page 3 ...

Page 4: ...HO Time 20 Seconds 10 RTE Time 20 Seconds DHO Time 40 Seconds 01 RTE Time 30 Seconds DHO Time 60 Seconds 11 RTE Time 45 Seconds DHO Time 90 Seconds Enrolling the M1KAM with the control Once the address is set and the M1KAM powered up it will be necessary to manually ENROLL the new device so that the M1 Control knows it is present This is accomplished either from keypad programming Menu 1 Bus Modul...

Page 5: ...tial is rejected the Keypad will produce a low error tone and display Code Not Authorized Redo The most common causes for rejection are A The credential has already been enrolled duplicate codes are not allowed or B The facility code in the credential is not the same brand or is not compatible with the reader Some manufacturers credentials are not readable by other brands of readers 9 After the cr...

Page 6: ...CESS are both enabled Whenever And Then Rules As mentioned above an ACCESS event flag does not actually do anything other than log unless there has been a Whenever And Then Rule written to tell the control what it is suppose to do Rules are written using the ElkRP Programming Software An Access event can be used to create virtually any desired reaction i e turn on an output a light close open a re...