29
ness Guardpost installation & Programming
CeNtrAL StAtIoN reportINg operAtIoN
If enabled, Guardpost reports alarms to a central monitoring station via the GSM
network in Contact ID format.
There are 2 phone numbers, a primary number PHONE1 and a secondary number
PHONE2. Reports are usually sent on the primary number but if the dialler is
unsuccessful in connecting, it will dial the secondary number.
A client account number is allocated by the monitoring company to identify the
customer. The client account number must be programmed into the system.
GUARDPOST transmits the next message on the queue, and if no acknowledge is
received from the monitoring station, GUARDPOST re-transmits the message for a
total of 10 attempts before displaying a dialler fault. Then, it will try again in 5 minutes,
then, another 4 times every 1 hour. If still unsuccessful, GUARDPOST ceases
transmitting until a new event occurs and raises a system alarm.
Contact ID reporting format takes the form:
SSSS 18 Q xyZ GG CCC e
SSSS
4 digit Client Account number
18
Uniquely identifies this format as Contact ID
Q
Event qualifier (1 = New alarm or Open; 3 = Restore or Close)
XYZ
Event code (hexadecimal)
GG
Group code. (always 00)
CCC
Sensor/key ID + offset, or Type number (decimal)
E
Error check
Program option
event Code (xyZ)
device iD, or Type
number (CCC)
SENS 1-23 = ALARM
SENS 1-23 = HOME
SENS 1-23 = HOME 2
SENS 1-23 = ACHIME
SENS 1-23 = HCHIME
130 Burglary
0 + ID
SENS 1-23 = FIRE
133 24 hour
50 + ID
Always enabled (unless auto-excluded at power-up)
137 Siren box tamper (Main unit)
106
Always enabled
383 Tamper (Sensor)
350 + ID
KEY 1-23 = KEY
120 Panic by user
300 + ID
KEY 1-23 = DURESS
121 Duress by user
400 + ID
KEY 1-23 = MEDICAL
101 Medical pendant
650 + ID
RADJAM = ON or
RADSUB = ON
355 Radio jamming
105
SUPVIS not = OFF
355 Radio supervision poll fail (Device)
200 + ID Detector
500 + ID Fixed Panic Button
LOWBAT = MAIN
LOWBAT = ALL
302 Main unit low battery
107
LOWBAT = SENSOR LOWBAT = ALL
384 Radio device low battery
0 + ID
Always enabled
309 Main unit battery test fail
108
OPEN = ON
401 Open/Close with user ID
0 + ID
Always enabled
406 Cancel of alarm message
0 + ID
contact id reporting table
contact id reporting Format
Gsm
contact id
message