T E S T I N G
We strongly suggest that you should carry out a full test of your
alarm system at a minimum 6 monthly interval.
You should Arm your SecurityGuard and test that each of your
PIR and Reed Switch detectors triggers an alarm as
programmed. A test procedure is described for each detector
in the replacing batteries section of this manual.
You could also check that your sirens are fully functional by
triggering an Emergency alarm from your Radio Key.
C L E A N I N G
Do not clean SecurityGuard with solvents like benzine or
thinners and do not use commercial spray pack cleaners as the
chemicals may attack the polycarbonate housing of
SecurityGuard.
A light dusting and if necessary warm
soapy water should only be used for
cleaning.
The same applies for your Radio Key,
PIR and Reed Switch housings.
I N S E C T S
Take particular care that insects like spiders and moths are
not forming webs or similar around any of the PIR detectors
including SecurityGuards inbuilt
detector. Insects can cause false
alarms. Brush away any spider webs
and if insects appear to be a problem
spray around the detector with a
surface insect spray.
Do Not Spray Directly Onto The
Detector or Lens Area !
21
M A I N T E N A N C E
B A T T E R I E S
Your PIR, Reed Switch and Radio Key batteries should last
approximately 2 years under normal usage when you use the
recommended Lithium batteries. We would advise that you
replace the batteries at this interval even if you have not
received a Low Battery warning.
S P E C I F I C A T I O N S
SecurityGuard
Model No
SG
II
Weight 2.4
KG
Dimensions
800 x 115 x 80 mm
Radio Frequency 303.875 Mhz. Aus, USA, Canada
Radio Frequency 418 Mhz. UK 433 Mhz. Europe
Siren
> 120 db @ 1 metre
Display
Dual 7 Segments
Battery
12 V Sealed Lead Acid 2.8 - 3.2 AH
Battery Charger
Voltage in
220v - 260v A.C. Aus, UK
Voltage in
110v - 130v A.C. USA, Canada
Voltage out
17 V A.C. @ 300 mA
Radio Key
Frequency
303.875 Mhz. Aus, USA, Canada
Frequency
418 Mhz. UK 433 Mhz. Europe
Battery
3V Lithium Coin Cell
12 V Alkaline (International Key)
Transmit Power 10 uW PEP MAX. Aus, USA, Canada
Transmit Power 100 mW PEP MAX. UK
P.I.R.
Frequency
303.875 Mhz. Aus, USA, Canada
Frequency
418 Mhz. UK 433 Mhz. Europe
Battery
9 V Lithium
Transmit Power 10 uW PEP MAX. Aus, USA, Canada
Transmit Power 100 mW PEP MAX. UK
Reed Switch
Frequency
303.875 Mhz. Aus, USA, Canada
Frequency
418 Mhz. UK 433 Mhz. Europe
Battery
3V Lithium Coin Cell ( Mini Reed )
9V Lithium (Shock Reed)
Transmit Power 10 uW PEP MAX. Aus, USA, Canada
Transmit Power 100 mW PEP MAX. UK
Manufactured in Australia by Ness Security Products Pty Ltd.
NOTE:
Specifications subject to change without notice in the
course of further development.
OFF
ON