Maintenance
Measuring closing force
Procedure:
1 Switch on machine.
2 After warming up, leave 150 ml of water
to flow through to heat up the jaw.
3 Insert capsule.
4 Attach spring balance to the middle of the
closing lever.
5 Press down closing lever with the aid of
the spring balance until the closing lever
is closed.
Ensure that the spring action of
closing is not taken into account.
6 Read off value. Repeat measurement
several times as necessary.
Closing force for new appliance: 25N ± 5N
If the closing force is less than
10N, replace capsule cage,
pyramid plate and support.