Chapter 1 - System Description
WILINK I MODULAR BASE STATION SYSTEM MANUAL
16
1.5.5
Configuration and Management
Table 1-10: Configuration and Management
Item
Description
Out Of Band (OOB) Management
Telnet via Management port
SNMP via Management port
Monitor port
In Band (IB) Management via Data
Port
SNMP
Telnet
SNMP Agents
SNMP ver 1 client
MIB II (RFC 1213), Private WILINK I MIBs
Authentication
X509v3 digital certificate
Software upgrade
Using TFTP
Configuration upload/download
Using TFTP
1.5.6
Standards Compliance, General
Table 1-11: Standards Compliance, General
Type
Standard
EMC
ETSI EN 301 489-1
Safety
EN 60950 (CE)
IEC 60 950 US/C (TUV)
Environmental
ETS 300 019:
Part 2-1 T 1.2 & part 2-2 T 2.3 for indoor & outdoor
Part 2-3 T 3.2 for indoor
Part 2-4 T 4.1E for outdoor
Radio
ETSI EN 301 753 V.1.1.1
ETSI EN 301 021 V.1.6.1