Chapter 4 - Operation and Administration
WILINK I MODULAR BASE STATION SYSTEM MANUAL
168
Table 4-22: NPU Monitor Parameters Summary
Parameter
Range
Default
Run-Time
Updated
Data Port Subnet
Mask
IP address
255.255.255.0
No
Data Port Gateway
IP address
0.0.0.0
No
Data Port
Management VLAN
ID
0-4094 or Null for No VLAN
Null
No
Data Port Speed
1 – 100 Mbps
2 – 1 Gbps
100 Mbps
No
Data Port
Management Traffic
Enable/Disable
1 – Disable
2 – Enable
Enable No
Authorized Manager
IP Address
IP address
NA
Yes
Authorized Manager
Send Traps
1 – Disable
2 – Enable
NA Yes
Authorized Manager
Read Community
Up to 23 printable characters, case
sensitive
NA Yes
Authorized Manager
Write Community
Up to 23 printable characters, case
sensitive
NA Yes
Bridge Aging Time
1 – 1440 minutes or null for no aging
10 minutes
Yes
DRAP TTL Retries
1 – 100
4
Yes
Radio Cluster Parameters
Radio Cluster ID
1 – 6
Yes
Name
Up to 32 printable characters
Null
Yes
Location
1 to 255 printable characters
The string defined for
the Location
parameter in Base
Station menu
Yes
Sector Heading
0 – 359 (degrees)
0
Yes
Sector Beam Width
0 – 359 (degrees)
90
Yes