Neptune ProCoder Quick Install Manual Download Page 19

10: What to Do if There is a Leak

Refer to the following checklist if there is a leak.

Check all faucets for possible leaks.

Check all toilets and toilet valves.

Check the ice maker and water
dispenser.

Check the yard and surrounding
grounds for a wet spot or indication of
a pipe leaking.

Table 5: Checklist for Leaks

11: If a Continuous Leak is Repaired

If a continuous leak is found and repaired, complete
the following steps.

1. Use no water for at least 15 minutes.

2. Check the sweep hand.

If the sweep hand is not moving, then a continuous
leak is no longer occurring.

- 17 -

Summary of Contents for ProCoder

Page 1: ...ProCoder Quick Install Guide...

Page 2: ......

Page 3: ...oth the homeowner and the utility can use the following features l Mechanical wheel bank for an absolute visual reading l Eight digits for billing l Sweep hand for extreme low flow detection and direc...

Page 4: ...e to the encoder register s terminals as described in the manufacturer s instructions using this color code l Black B l Green G l Red R 2 Remove the terminal cover with a flat head screw driver Figure...

Page 5: ...posed bare wires Neptune recommends Novagard G661 or Dow Corning Compound 4 Novagard may cause irritation to eyes and skin If swallowed do not induce vomiting dilute with one to two glasses of water o...

Page 6: ...at 800 647 4832 3 Place the terminal cover on register ensuring the wire is routed through the strain relief Figure 6 Placing the Cover on the Register Figure 7 Snapping the Cover in Place 4 Snap the...

Page 7: ...re 8 Installation Components Figure 9 Scotchlok Connector 1 Hold the Scotchlok between the index finger and thumb with the red cap facing down 2 Take one non stripped black wire from the pigtail and o...

Page 8: ...Table 2 on page 12 for part numbers 4 Check to ensure that the wires are still fully seated in the connector before crimping the connector Figure 12 illustrates improper connections due to wires not b...

Page 9: ...lster Black G Green R Red B Badger Table 1 Color Codes for Wires 7 After you connect all three color wires read the encoder register to ensure proper connections and the receptacle MIU is functioning...

Page 10: ...osed to finish the installation 4 Installation Instructions for Networked Receptacle Dual Port MIUs Enhanced R900 v4 MIUs are not dual port capable These instructions only apply to v3 MIUs The Dual Po...

Page 11: ...de of the compound and the low LO flow or disc side of the compound l The settings can also be used to designate the primary HI and secondary LO meters in a dual set application Programming the HI Reg...

Page 12: ...egister Use the Neptune Field Programmer to select the ProRead Program tab for programming Figure 18 LO Register 1 Select RF Compound LO format 2 Match the Connectivity 2W 3 Match the Dial Code 65 4 T...

Page 13: ...ee colors have been successfully connected See Figure 19 Figure 19 Interconnection of Like Terminals l Remove any bare or non insulated wire Make sure that you only insert insulated wires into the spl...

Page 14: ...advantage indicated within the parentheses Manufacturer Manufacturer s Model Number 3M E 9R 10 1 To reduce fatigue use a tool within each splicing group with the highest mechanical advantage indicate...

Page 15: ...Sweep Hand The sensitive sweep hand provides a visual representation of extreme low flows as well as reverse flow Depending on the size and type of ProCoder register a specific multiplier is present T...

Page 16: ...rcumstances To better help you identify a possible leak Table 3 contains some common causes of leaks Possible Cause of Leak Intermittent Leak Continuous Leak Outside faucet garden or sprinkler system...

Page 17: ...machine leaking Dishwasher leaking Hot water heater leaking Watering yard for more than eight hours Continuous pet feeder Water cooled air conditioner or heat pump Filling a swimming pool Any continuo...

Page 18: ...e which of the following conditions exist If Then The sweep hand is moving slowly in a clockwise direction Water is running very slowly The sweep hand is moving quickly Water is running The sweep hand...

Page 19: ...water dispenser Check the yard and surrounding grounds for a wet spot or indication of a pipe leaking Table 5 Checklist for Leaks 11 If a Continuous Leak is Repaired If a continuous leak is found and...

Page 20: ...ag Resets After 35 Days Based on reverse movement of the eighth digit the eighth digit is variable based on the meter size No backflow event Eighth digit reversed less than one digit Minor backflow ev...

Page 21: ...h digit incremented in 50 of the 96 15 minute intervals Continuous leak Eighth digit incremented in all of the 96 15 minute intervals Consecutive Days with Zero Consumption Flag Resets After 35 Days N...

Page 22: ...nical Support PIN 3 Enter the six digit PIN and press 4 Select one of the following options l Press 2 for Technical Support l Press 3 for maintenance contracts or renewals l Press 4 for Return Materia...

Page 23: ...___________________________________________________________ ________________________________________________________________ ________________________________________________________________ __________...

Page 24: ...____________________________________ ________________________________________________________________ ________________________________________________________________ _________________________________...

Page 25: ......

Page 26: ...QI ProCoder 02 19 Part No 13706 001 Copyright 2017 2019 Neptune Technology Group Inc Neptune is a registered trademark of Neptune Technology G9roup Inc...

Reviews: