background image

HOW TO……..

Set for Single Door mode, with Super-open password 

Press and Hold * for 2-

3 Sec’s until Red 

LED Flashes 

<Enter>Admin Password # 

03 1#  - Single door mode (Default) 

00 (8 digits #) Must be 8 digit Super-open password 

 

       - 

Exit Menu’s

 

Use Super-open password 

Press and Hold * for 2-3 

Sec’s until Red LED Flashes

 

<Enter>Admin Password # 

33

 

0# 

- Disable all User Access

 

       - Exit Menu

No User Codes will operate the Output 

<Enter> 8 digit Super-open password to operate the Output 

<Enter>Admin Password # 

33

 

1# 

- Enable all User Access

 

       - 

Exit Menu’s

 

All User Codes will operate the Output, Super-open password will also operate Output. 

HOW TO……..

Reset Keypad Admin Code to Defaults 

Power off Keypad

Press & hold * key whilst power up, until you hear 2 beeps and see Amber LED

Release * Key and this will Default the Installer Code

Press & Hold * key for 2-3 Secs and wait for Flashing Red LED, then release

00 <Enter> New 6-digit PIN # <Enter> New 6-digit PIN # <Green> LED will confirm

Restore Default Settings 

Press & Hold * key for 2-3 Secs and wait for Flashing Red LED, then release

<Enter> 6-digit PIN # <Green> LED will confirm

09 0000 # - Restore default settings, admin password and user information
remain unchanged

20 0000 #  - Delete all users in Zone 1 and Zone 2

 

-

Exit Menu’s

NEPTUNE 

Quick Reference Guide

Summary of Contents for ACKPWB6K

Page 1: ...her operations After inputting correct Master code the LED light will flash green for one time and then back to red flashing status HOW TO Add a PIN User Press and Hold for 2 3 Sec s until Red LED Flashes Enter Admin Password Specified ID number and input 4 6 digits PIN to add user 11 ID User PIN User 1 ID User PIN User 2 Multiple Users keep adding until finished Exit Menu s Eg 11 1 1111 User ID 1...

Page 2: ...supply should set to min time to ensure the actual Unlock time match with user s settings HOW TO Set for Wiegand Reader Press and Hold for 2 3 Sec s until Red LED Flashes Enter Admin Password 03 0 Reader Mode 04 7 Read EM HID IC cards Default Note This Model only supports EM HID 64 4 1 5 digit key key buffered output FC 1 5 Digit PIN Code 64 0 1 10 digits key 1 10 Digit PIN Code 60 xxx 0 255 Set f...

Page 3: ...User Codes will operate the Output Super open password will also operate Output HOW TO Reset Keypad Admin Code to Defaults Power off Keypad Press hold key whilst power up until you hear 2 beeps and see Amber LED Release Key and this will Default the Installer Code Press Hold key for 2 3 Secs and wait for Flashing Red LED then release 00 Enter New 6 digit PIN Enter New 6 digit PIN Green LED will co...

Page 4: ...ctive low which can drive the current below 1Amp 4 1 26 Set the key whether it can be used doorbell key 56 1 the key can be used as doorbell key Note When the key is used as doorbell key if the key is the first key then it is doorbell function If the key is after the digital key then it is confirm function 4 1 27 Set doorbell key mode 57 1 the doorbell key is valid but without volume 57 2 the door...

Page 5: ...Card Max 3 Cards for this Operation Note If only one Authorization Card is required simply read 1 Card and Exit programming Exit Menu s To test this function you would have existing PIN CODE or Card Users working on the Keypad If you present the Authorisation Card the Keypad will respond with 2 Short Beeps to Lock Users out When you present the Authorisation Card a second time the Keypad will resp...

Page 6: ... to Single door mode 03 2 Set to Double doors mode 4 1 x xx To add user card or PIN Specify ID number and read card to add user 11 ID read card ID read card Specified ID number and input 4 6 digits PIN to add user 11 ID User PIN ID User PIN Note ID number are 1 5 digits between 1 20000 User PIN in zone 1 are any 4 6 digits except 1234 Not to be used for USER PIN User PIN in Zone 2 are any 7 digits...