technical data of pumps:
base unit
voltage
emission / admission in kW
maximum flow rate l / min. max.
flow after 2 m in m / sec.
current consumption
preliminary fuse
line from the network
cable to the pump
motor protection from the factory
There are rules necessarily to be observed by ÖVE (VDE), as well as the local EW when in-
stalling the system.
The installation may exclusively be carried out by a licensed electrician. In power line an
all- pole seperator with a contact gap of at least 3 mm must be provided.
In the power line a residual current circuit breaker with a rated leakage current of <= 30
mA must be provided.
Attention! Pay attention to the motor direction of rotation (direction of rotation arrow)
The switching device must be installed in a place easily accessible and dry.
The instructions and guidelines given in this document correspond to the state of technology
and aren`t any replacement for a consultation or the carrying out by pool specialist shops
or the corresponding building divisions and construction companies in compliance of cur-
rent building regulations. In the case of complaint, please enclose the check number and a
copy of the invoice.
ST 700
ST 750
ST 770
230V/50Hz
3~230/400/50Hz.
1,6 / 2
2,1 / 2,6
2,6 / 3
700
800
950
1,5
1,8
1,9
see pump-nameplate
16 A träge
3 x 1,5 mm²
5 x 2,5 mm²
3 x 1,5 mm²
4 x 2,5 mm²
10 A
4,5 A
6,1 A