To protect all the threaded parts, you have to cover the implementations with the enclosed,
self-adhesive building protection.
The run-pot must be fixed approximately 250 mm below the water surface.
Both built-in pots must be mounted flush to the inside of the pool (note a possible isolation)
The site of the pump must be chosen as close as possible to the implementations. In addi-
tion, make sure that the pump is mounted voltage- and vibrationfree on solid base or a
suitable panel. Furthermore, you have to provide an outflow possibility as well as an ade-
quate ventilation to prevent a flooding of the site. That`s the only way how a trouble-free
operation can be guaranteed.
Stick the air hose with the check valve in the therefore provided opening of the built-in pot.
Make sure that if extensions may be necessary, keep them short and only bends but never
angles must be used.
Similarly, a piping of the next larger nominal size should be worth to compensate possible
pipeline resistors.
The pneumatic hose must be placed on the electronic schematic.
must be above the level of the water